Source:http://linkedlifedata.com/resource/pubmed/id/11318409
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
1
|
pubmed:dateCreated |
2001-4-24
|
pubmed:abstractText |
A high-performance size-exclusion chromatographic method was developed, validated and implemented for simultaneous and quantitative determination of albumin and myoglobin along with inulin, vancomycin and creatinine in dialysate and ultrafiltrate samples from in vitro hemodialysis experiments. The experimental parameters including mobile phase pH, ionic strength, detection wavelength, flow-rate, injection volume were first optimized for the determination of albumin, myoglobin, inulin, vancomycin and creatinine. The peak height ratio and detection limits of the proteins were then comparatively studied at 210, 254 and 280 nm by UV and diode array detection. The method was further validated by evaluating the linearity, precision and accuracy of the proteins. The assay was finally implemented to the simultaneous and quantitative determination of the proteins in dialysate and ultrafiltrate samples.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical |
http://linkedlifedata.com/resource/pubmed/chemical/Albumins,
http://linkedlifedata.com/resource/pubmed/chemical/Creatinine,
http://linkedlifedata.com/resource/pubmed/chemical/Dialysis Solutions,
http://linkedlifedata.com/resource/pubmed/chemical/Inulin,
http://linkedlifedata.com/resource/pubmed/chemical/Myoglobin,
http://linkedlifedata.com/resource/pubmed/chemical/Vancomycin
|
pubmed:status |
MEDLINE
|
pubmed:month |
Apr
|
pubmed:issn |
1387-2273
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:day |
15
|
pubmed:volume |
754
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
141-51
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading |
pubmed-meshheading:11318409-Albumins,
pubmed-meshheading:11318409-Chromatography, Gel,
pubmed-meshheading:11318409-Creatinine,
pubmed-meshheading:11318409-Dialysis Solutions,
pubmed-meshheading:11318409-Inulin,
pubmed-meshheading:11318409-Myoglobin,
pubmed-meshheading:11318409-Reproducibility of Results,
pubmed-meshheading:11318409-Rheology,
pubmed-meshheading:11318409-Spectrophotometry, Ultraviolet,
pubmed-meshheading:11318409-Ultrafiltration,
pubmed-meshheading:11318409-Vancomycin
|
pubmed:year |
2001
|
pubmed:articleTitle |
Determination of albumin and myoglobin in dialysate and ultrafiltrate samples by high-performance size-exclusion chromatography.
|
pubmed:affiliation |
Purdue University, School of Pharmacy and Pharmacal Sciences, Department of Pharmacy Practice, Wishard Memorial Hospital, Indianapolis, IN 46202, USA.
|
pubmed:publicationType |
Journal Article,
Research Support, Non-U.S. Gov't
|