pubmed-article:122882 | rdf:type | pubmed:Citation | lld:pubmed |
pubmed-article:122882 | lifeskim:mentions | umls-concept:C0042497 | lld:lifeskim |
pubmed-article:122882 | lifeskim:mentions | umls-concept:C0020259 | lld:lifeskim |
pubmed-article:122882 | lifeskim:mentions | umls-concept:C0038777 | lld:lifeskim |
pubmed-article:122882 | lifeskim:mentions | umls-concept:C0201879 | lld:lifeskim |
pubmed-article:122882 | lifeskim:mentions | umls-concept:C0439962 | lld:lifeskim |
pubmed-article:122882 | lifeskim:mentions | umls-concept:C0242485 | lld:lifeskim |
pubmed-article:122882 | lifeskim:mentions | umls-concept:C0376558 | lld:lifeskim |
pubmed-article:122882 | lifeskim:mentions | umls-concept:C1539220 | lld:lifeskim |
pubmed-article:122882 | lifeskim:mentions | umls-concept:C0557854 | lld:lifeskim |
pubmed-article:122882 | lifeskim:mentions | umls-concept:C0001861 | lld:lifeskim |
pubmed-article:122882 | lifeskim:mentions | umls-concept:C1521827 | lld:lifeskim |
pubmed-article:122882 | lifeskim:mentions | umls-concept:C0179630 | lld:lifeskim |
pubmed-article:122882 | lifeskim:mentions | umls-concept:C0336640 | lld:lifeskim |
pubmed-article:122882 | lifeskim:mentions | umls-concept:C0079809 | lld:lifeskim |
pubmed-article:122882 | lifeskim:mentions | umls-concept:C1705968 | lld:lifeskim |
pubmed-article:122882 | lifeskim:mentions | umls-concept:C1553461 | lld:lifeskim |
pubmed-article:122882 | pubmed:issue | 1 | lld:pubmed |
pubmed-article:122882 | pubmed:dateCreated | 1975-4-8 | lld:pubmed |
pubmed-article:122882 | pubmed:abstractText | Four systems have been fabricated to measure the effective service life of respirator cartridges and canisters. The four systems employ carbon monoxide, sulfur dioxide/nitrogen dioxide, ammonia/methylamine, and chlorine/hydrogen chloride as contaminants. Each system produces test concentrations in the low percentage range (typically 0.05 to 3.0%) at flow rates of 32 and 64 liters/min and at relative humidities between 20 and 95%. Suitable anlyzers have been provided to measure the downstream concentration from 1 to 500 ppm as a function of time. Holders have been designed to accommodate the wide size variation of commercially available cartridges and canisters. | lld:pubmed |
pubmed-article:122882 | pubmed:language | eng | lld:pubmed |
pubmed-article:122882 | pubmed:journal | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:122882 | pubmed:citationSubset | IM | lld:pubmed |
pubmed-article:122882 | pubmed:chemical | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:122882 | pubmed:chemical | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:122882 | pubmed:chemical | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:122882 | pubmed:chemical | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:122882 | pubmed:chemical | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:122882 | pubmed:chemical | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:122882 | pubmed:chemical | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:122882 | pubmed:status | MEDLINE | lld:pubmed |
pubmed-article:122882 | pubmed:month | Jan | lld:pubmed |
pubmed-article:122882 | pubmed:issn | 0002-8894 | lld:pubmed |
pubmed-article:122882 | pubmed:author | pubmed-author:TaylorR DRD | lld:pubmed |
pubmed-article:122882 | pubmed:author | pubmed-author:NelsonG OGO | lld:pubmed |
pubmed-article:122882 | pubmed:author | pubmed-author:SwisherL ELE | lld:pubmed |
pubmed-article:122882 | pubmed:author | pubmed-author:BiglerB EBE | lld:pubmed |
pubmed-article:122882 | pubmed:issnType | Print | lld:pubmed |
pubmed-article:122882 | pubmed:volume | 36 | lld:pubmed |
pubmed-article:122882 | pubmed:owner | NLM | lld:pubmed |
pubmed-article:122882 | pubmed:authorsComplete | Y | lld:pubmed |
pubmed-article:122882 | pubmed:pagination | 49-56 | lld:pubmed |
pubmed-article:122882 | pubmed:dateRevised | 2006-11-15 | lld:pubmed |
pubmed-article:122882 | pubmed:meshHeading | pubmed-meshheading:122882-A... | lld:pubmed |
pubmed-article:122882 | pubmed:meshHeading | pubmed-meshheading:122882-T... | lld:pubmed |
pubmed-article:122882 | pubmed:meshHeading | pubmed-meshheading:122882-H... | lld:pubmed |
pubmed-article:122882 | pubmed:meshHeading | pubmed-meshheading:122882-C... | lld:pubmed |
pubmed-article:122882 | pubmed:meshHeading | pubmed-meshheading:122882-V... | lld:pubmed |
pubmed-article:122882 | pubmed:meshHeading | pubmed-meshheading:122882-C... | lld:pubmed |
pubmed-article:122882 | pubmed:meshHeading | pubmed-meshheading:122882-A... | lld:pubmed |
pubmed-article:122882 | pubmed:meshHeading | pubmed-meshheading:122882-H... | lld:pubmed |
pubmed-article:122882 | pubmed:meshHeading | pubmed-meshheading:122882-A... | lld:pubmed |
pubmed-article:122882 | pubmed:meshHeading | pubmed-meshheading:122882-S... | lld:pubmed |
pubmed-article:122882 | pubmed:meshHeading | pubmed-meshheading:122882-R... | lld:pubmed |
pubmed-article:122882 | pubmed:meshHeading | pubmed-meshheading:122882-N... | lld:pubmed |
pubmed-article:122882 | pubmed:meshHeading | pubmed-meshheading:122882-E... | lld:pubmed |
pubmed-article:122882 | pubmed:year | 1975 | lld:pubmed |
pubmed-article:122882 | pubmed:articleTitle | Preparation of mixtures of humidified air with CO, SO2, NO2, NH3, NH2CH3, Cl2, and HCl to measure respirator cartridge and canister service life. | lld:pubmed |
pubmed-article:122882 | pubmed:publicationType | Journal Article | lld:pubmed |
pubmed-article:122882 | pubmed:publicationType | Research Support, U.S. Gov't, Non-P.H.S. | lld:pubmed |