Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
2
pubmed:dateCreated
1982-8-14
pubmed:abstractText
A comparative study has been realized to test the accuracy of ultrasonography and scintigraphy for detecting the presence of liver metastases in 305 patients with colorectal carcinomas. Presence or absence of hepatic metastases has been affirmed by laparotomy and biopsy. In the 47 cases with metastases, the sensitivity of ultrasonography was 93%, that of scintigraphy being 76%. In 258 cases without metastases the specificity of ultrasonography was 97%, that of scintigraphy being 92%. These results, confirmed by report in the published literature, show that ultrasonography should be the first examination for suspected hepatic metastases.
pubmed:language
fre
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:month
Feb
pubmed:issn
0221-0363
pubmed:author
pubmed:issnType
Print
pubmed:volume
63
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
97-100
pubmed:dateRevised
2006-11-15
pubmed:meshHeading
pubmed:year
1982
pubmed:articleTitle
[Comparative study of ultrasonography and scintigraphy in liver metastases detection in cases of colorectal carcinoma (author's transl)].
pubmed:publicationType
Journal Article, Comparative Study, English Abstract