rdf:type |
|
lifeskim:mentions |
|
pubmed:issue |
1
|
pubmed:dateCreated |
1986-3-12
|
pubmed:abstractText |
The accuracy of breast ultrasound using all purpose static beta-scanning equipment has been compared with mammography. Ultrasound was found to be both more sensitive (93%:82%) and specific (95%:89%) in a large retrospective series of 1000 patients undergoing investigation for symptomatic breast disease. In a smaller prospective and consecutive series of 142 patients undergoing surgery where histological proof was obtained ultrasound was also found to be more sensitive (91%:81%) and specific (81%:69%). In both studies, the greater accuracy of ultrasound was attributed to its ability to diagnose lesions hidden in X-ray dense breasts and where mammography had revealed featureless asymmetical densities of uncertain nature. In these instances ultrasound may have a significant role to play as an adjunct to mammography in the preoperative assessment of breast lesions.
|
pubmed:commentsCorrections |
http://linkedlifedata.com/resource/pubmed/commentcorrection/3511831-14814827,
http://linkedlifedata.com/resource/pubmed/commentcorrection/3511831-3905192,
http://linkedlifedata.com/resource/pubmed/commentcorrection/3511831-402833,
http://linkedlifedata.com/resource/pubmed/commentcorrection/3511831-4362108,
http://linkedlifedata.com/resource/pubmed/commentcorrection/3511831-6107461,
http://linkedlifedata.com/resource/pubmed/commentcorrection/3511831-6254110,
http://linkedlifedata.com/resource/pubmed/commentcorrection/3511831-6254111,
http://linkedlifedata.com/resource/pubmed/commentcorrection/3511831-6274469,
http://linkedlifedata.com/resource/pubmed/commentcorrection/3511831-6298858,
http://linkedlifedata.com/resource/pubmed/commentcorrection/3511831-6600356,
http://linkedlifedata.com/resource/pubmed/commentcorrection/3511831-6600557,
http://linkedlifedata.com/resource/pubmed/commentcorrection/3511831-6601422,
http://linkedlifedata.com/resource/pubmed/commentcorrection/3511831-661900,
http://linkedlifedata.com/resource/pubmed/commentcorrection/3511831-6742737,
http://linkedlifedata.com/resource/pubmed/commentcorrection/3511831-6743977,
http://linkedlifedata.com/resource/pubmed/commentcorrection/3511831-6878706
|
pubmed:language |
eng
|
pubmed:journal |
|
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Jan
|
pubmed:issn |
0035-8843
|
pubmed:author |
|
pubmed:issnType |
Print
|
pubmed:volume |
68
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
19-22
|
pubmed:dateRevised |
2009-11-18
|
pubmed:meshHeading |
|
pubmed:year |
1986
|
pubmed:articleTitle |
The accuracy of ultrasound in the diagnosis of breast disease.
|
pubmed:publicationType |
Journal Article,
Comparative Study
|