Source:http://linkedlifedata.com/resource/pubmed/id/19302512
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
3
|
pubmed:dateCreated |
2009-7-1
|
pubmed:abstractText |
A time- and cost-effective sweat casting method using the forearm as test site to assess the efficacy of several anti-perspirant formulations with a low number of test subjects has been evaluated and qualified. The imprint sweat casting method is based on a 2-component silcone-imprint technique to measure the efficacy of more than eight products in parallel with the same test subject. In studies using aluminum chlorohydrate (ACH) formulations as test anti-perspirants, a clear-cut correlation could be demonstrated between sweat gland activities measured by the imprint method and gravimetric measurement of sweat gland activities. Concentration-dependent inhibition of sweat gland activity could be observed with the imprint technique up to an ACH concentration of 15%, and all formulations containing 2% ACH or above resulted in statistically significant reduction of sweat gland activity (P < 0.001) when compared with untreated control areas. Furthermore, the SDs of individual studies using the imprint technique were in a range of +/-20% of sweat gland activity, which can be regarded rather low for in vivo measurements of a complex process like sweat secretion. A group-wise comparison between the measurements of anti-perspirant activity as determined by the imprint protocol and the Food and Drug Administration (FDA) Guideline compliant gravimetric hot-room protocol revealed that the test results for anti-perspirant activity obtained with the imprint protocol are similar to those obtained with the hot-room protocol. Moreover, the data generated with the imprint protocol have a high predictive value for the outcome of a later guideline-compliant hot-room test. As the imprint casting method tends to be a little more sensitive for formulations with low anti-perspirant activity, and seems to be associated with less interassay variability than the standard gravimetric hot-room test, the imprint casting method may select products which later fail to pass the standard gravimetric hot-room test. Meanwhile the imprint sweat casting has proven to be a robust method useful to support efficacy-oriented product development. Therefore, in later stages of utilization it might even evolve into an efficient claim substantiation tool.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Jun
|
pubmed:issn |
1468-2494
|
pubmed:author | |
pubmed:issnType |
Electronic
|
pubmed:volume |
31
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
183-92
|
pubmed:meshHeading |
pubmed-meshheading:19302512-Adolescent,
pubmed-meshheading:19302512-Adult,
pubmed-meshheading:19302512-Aged,
pubmed-meshheading:19302512-Antiperspirants,
pubmed-meshheading:19302512-Female,
pubmed-meshheading:19302512-Humans,
pubmed-meshheading:19302512-Male,
pubmed-meshheading:19302512-Middle Aged,
pubmed-meshheading:19302512-Reproducibility of Results,
pubmed-meshheading:19302512-Sweat,
pubmed-meshheading:19302512-Young Adult
|
pubmed:year |
2009
|
pubmed:articleTitle |
Qualification of a precise and easy-to-handle sweat casting imprint method for the prediction and quantification of anti-perspirant efficacy.
|
pubmed:affiliation |
Beiersdorf AG, Hamburg, Germany. Reza.Keyhani@Beiersdorf.com
|
pubmed:publicationType |
Journal Article,
Research Support, Non-U.S. Gov't
|