Source:http://linkedlifedata.com/resource/pubmed/id/18992883
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions |
umls-concept:C0006901,
umls-concept:C0016315,
umls-concept:C0022257,
umls-concept:C0025663,
umls-concept:C0032520,
umls-concept:C0205250,
umls-concept:C0205374,
umls-concept:C0332324,
umls-concept:C0370003,
umls-concept:C0596607,
umls-concept:C0920585,
umls-concept:C0936012,
umls-concept:C1511790,
umls-concept:C2347026
|
pubmed:issue |
1-2
|
pubmed:dateCreated |
2008-12-1
|
pubmed:abstractText |
We present a sensitive, simple and robust on-chip transient isotachophoresis/capillary gel electrophoresis (tITP/CGE) method for the analysis of polymerase chain reaction (PCR) samples. Using chloride ions in the PCR buffer and N-2-hydroxyethylpiperazine-N'-2-ethanesulfonic acid (HEPES) in the background electrolyte, respectively, as the leading and terminating electrolytes, the tITP preconcentration was coupled with CGE separation with double-T shaped channel network. The tITP/CGE separation was carried out with a single running buffer. The separation process involved only two steps that were performed continuously with the sequential switching of four voltage outputs. The tITP/CGE method showed an analysis time and a separation efficiency comparable to those of standard CGE, while the signal intensity was enhanced by factors of over 20. The limit of detection of the chip-based tITP/CGE method was estimated to be 1.1 ng/mL of DNA in 1x PCR buffer using confocal fluorescence detection following 473 nm laser excitation.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Dec
|
pubmed:issn |
0021-9673
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:day |
19
|
pubmed:volume |
1214
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
165-70
|
pubmed:meshHeading |
pubmed-meshheading:18992883-DNA,
pubmed-meshheading:18992883-Electrophoresis,
pubmed-meshheading:18992883-Electrophoresis, Capillary,
pubmed-meshheading:18992883-Electrophoresis, Microchip,
pubmed-meshheading:18992883-Fluorescence,
pubmed-meshheading:18992883-Lasers,
pubmed-meshheading:18992883-Polymerase Chain Reaction,
pubmed-meshheading:18992883-Reproducibility of Results,
pubmed-meshheading:18992883-Sensitivity and Specificity
|
pubmed:year |
2008
|
pubmed:articleTitle |
Simplified transient isotachophoresis/capillary gel electrophoresis method for highly sensitive analysis of polymerase chain reaction samples on a microchip with laser-induced fluorescence detection.
|
pubmed:affiliation |
Bioengineering Center, Improve Medical Instrument's Co., Ltd., 510370 Guangzhou, China. ruark@126.com
|
pubmed:publicationType |
Journal Article,
Research Support, Non-U.S. Gov't
|