Source:http://linkedlifedata.com/resource/pubmed/id/18076891
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions |
umls-concept:C0017110,
umls-concept:C0057764,
umls-concept:C0057779,
umls-concept:C0183396,
umls-concept:C0302647,
umls-concept:C0370003,
umls-concept:C0439851,
umls-concept:C1533685,
umls-concept:C1552596,
umls-concept:C1555707,
umls-concept:C1705851,
umls-concept:C1880156,
umls-concept:C1947931,
umls-concept:C2347026,
umls-concept:C2347299,
umls-concept:C2348791,
umls-concept:C2752151,
umls-concept:C2828366
|
pubmed:issue |
1-2
|
pubmed:dateCreated |
2007-12-31
|
pubmed:abstractText |
Polychlorinated dibenzo-p-dioxins and dibenzofurans in crude extracts of fly ash and flue gas from municipal waste incinerators were quantified using a comprehensive multidimensional gas chromatograph (GC x GC) coupled to a high-resolution time-of-flight mass spectrometer (HR-TOFMS). For identification and quantification, we developed our own program to prepare 3D chromatograms of selected mass numbers from the data of the GC x GC/HR-TOFMS. Isolation of all congeners with a TCDD toxic equivalency factor from the other isomers by only one injection was confirmed. The instrumental detection limit of TCDD on the GC x GC/HR-TOFMS was 0.9 pg by the relative calibration method. Quantification of these substances in the crude extracts was achieved by direct injection to the GC x GC/HR-TOFMS. The results agree with the values obtained using a generic gas chromatography/high-resolution mass spectrometry (GC/HRMS) system. It was confirmed that measurement by high-resolution TOFMS and GC x GC effectively reduces interference from other chemicals.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical |
http://linkedlifedata.com/resource/pubmed/chemical/Benzofurans,
http://linkedlifedata.com/resource/pubmed/chemical/Carbon,
http://linkedlifedata.com/resource/pubmed/chemical/Coal Ash,
http://linkedlifedata.com/resource/pubmed/chemical/Dioxins,
http://linkedlifedata.com/resource/pubmed/chemical/Particulate Matter,
http://linkedlifedata.com/resource/pubmed/chemical/dibenzo(1,4)dioxin,
http://linkedlifedata.com/resource/pubmed/chemical/dibenzofuran
|
pubmed:status |
MEDLINE
|
pubmed:month |
Jan
|
pubmed:issn |
0021-9673
|
pubmed:author |
pubmed-author:AkihikoKusaiK,
pubmed-author:FushimiAkihiroA,
pubmed-author:HashimotoShunjiS,
pubmed-author:ItoHiroyasuH,
pubmed-author:KatsunoriAnezakiA,
pubmed-author:Masa-akiUbukataU,
pubmed-author:OtsukaHideyukiH,
pubmed-author:ShibataYasuyukiY,
pubmed-author:TakazawaYoshikatsuY,
pubmed-author:TanabeKiyoshiK,
pubmed-author:TanakaKazuoK
|
pubmed:issnType |
Print
|
pubmed:day |
18
|
pubmed:volume |
1178
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
187-98
|
pubmed:dateRevised |
2011-11-17
|
pubmed:meshHeading | |
pubmed:year |
2008
|
pubmed:articleTitle |
Quantification of polychlorinated dibenzo-p-dioxins and dibenzofurans by direct injection of sample extract into the comprehensive multidimensional gas chromatograph/high-resolution time-of-flight mass spectrometer.
|
pubmed:affiliation |
National Institute for Environmental Studies, 16-2 Onogawa, Tsukuba, Ibaraki 305-8506, Japan.
|
pubmed:publicationType |
Journal Article
|