pubmed:abstractText
We evaluated a new real-time PCR-based prototype assay for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae developed by Abbott Molecular Inc. This assay is designed to be performed on an Abbott m2000 real-time instrument system, which consists of an m2000sp instrument for sample preparation and an m2000rt instrument for real-time PCR amplification and detection. The limit of detection of this prototype assay was determined to be 20 copies of target DNA for both C. trachomatis and N. gonorrhoeae, using serially diluted linearized plasmids. No cross-reactivity could be detected when 55 nongonococcal Neisseria isolates and 3 non-C. trachomatis Chlamydia isolates were tested at 1 million genome equivalents per reaction. Concordance with the Roche Amplicor, BDProbeTec ET, and Gen-Probe APTIMA Combo 2 tests was assessed using unlinked/deidentified surplus clinical specimens previously analyzed with these tests. For C. trachomatis, concordance for positive results ranged from 93.7% to 100%, while concordance for negative results ranged from 98.2% to 100%. For N. gonorrhoeae, concordance for positive and negative results ranged from 91.4% to 100% and 99.3% to 100%, respectively. A workflow analysis of the prototype assay was conducted to obtain information on throughput under laboratory conditions. At 48 samples/run, the time to first result for both C. trachomatis and N. gonorrhoeae was 4.5 h. A total of 135 patient specimens could be analyzed in 8.9 h, with 75 min of hands-on time. This study demonstrated the technical and clinical feasibility of the new Abbott real-time PCR C. trachomatis/N. gonorrhoeae assay.
pubmed:commentsCorrections
http://linkedlifedata.com/resource/pubmed/commentcorrection/17202273-10523571, http://linkedlifedata.com/resource/pubmed/commentcorrection/17202273-10699004, http://linkedlifedata.com/resource/pubmed/commentcorrection/17202273-11015361, http://linkedlifedata.com/resource/pubmed/commentcorrection/17202273-11230419, http://linkedlifedata.com/resource/pubmed/commentcorrection/17202273-11325985, http://linkedlifedata.com/resource/pubmed/commentcorrection/17202273-11326027, http://linkedlifedata.com/resource/pubmed/commentcorrection/17202273-12354846, http://linkedlifedata.com/resource/pubmed/commentcorrection/17202273-12517865, http://linkedlifedata.com/resource/pubmed/commentcorrection/17202273-12574282, http://linkedlifedata.com/resource/pubmed/commentcorrection/17202273-12904360, http://linkedlifedata.com/resource/pubmed/commentcorrection/17202273-12904390, http://linkedlifedata.com/resource/pubmed/commentcorrection/17202273-12904416, http://linkedlifedata.com/resource/pubmed/commentcorrection/17202273-16455891, http://linkedlifedata.com/resource/pubmed/commentcorrection/17202273-2039031, http://linkedlifedata.com/resource/pubmed/commentcorrection/17202273-2252390, http://linkedlifedata.com/resource/pubmed/commentcorrection/17202273-3016782, http://linkedlifedata.com/resource/pubmed/commentcorrection/17202273-7852556, http://linkedlifedata.com/resource/pubmed/commentcorrection/17202273-9774550, http://linkedlifedata.com/resource/pubmed/commentcorrection/17202273-9854067, http://linkedlifedata.com/resource/pubmed/commentcorrection/17202273-9889224
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Mar
pubmed:issn
0095-1137
pubmed:author
pubmed:issnType
Print
pubmed:volume
45
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
747-51
pubmed:dateRevised
2009-11-18
pubmed:meshHeading
pubmed:year
2007
pubmed:articleTitle
Characteristics of the m2000 automated sample preparation and multiplex real-time PCR system for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.
pubmed:affiliation
Abbott Molecular Inc., Des Plaines, IL 60018, USA.
pubmed:publicationType