Source:http://linkedlifedata.com/resource/pubmed/id/17036780
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
10
|
pubmed:dateCreated |
2006-10-12
|
pubmed:abstractText |
An ultrasonic ring transducer system has been developed for experimental studies of scattering and imaging. The transducer consists of 2048 rectangular elements with a 2.5-MHz center frequency, a 67% -6 dB bandwidth, and a 0.23-mm pitch arranged in a 150-mm-diameter ring with a 25-mm elevation. At the center frequency, the element size is 0.30lambda x 42lambda and the pitch is 0.38lambda. The system has 128 parallel transmit channels, 16 parallel receive channels, a 2048:128 transmit multiplexer, a 2048:16 receive multiplexer, independently programmable transmit waveforms with 8-bit resolution, and receive amplifiers with time variable gain independently programmable over a 40-dB range. Receive signals are sampled at 20 MHz with 12-bit resolution. Arbitrary transmit and receive apertures can be synthesized. Calibration software minimizes system nonidealities caused by noncircularity of the ring and element-to-element response differences. Application software enables the system to be used by specification of high-level parameters in control files from which low-level hardware-dependent parameters are derived by specialized code. Use of the system is illustrated by producing focused and steered beams, synthesizing a spatially limited plane wave, measuring angular scattering, and forming b-scan images.
|
pubmed:grant | |
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Oct
|
pubmed:issn |
0885-3010
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
53
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
1707-18
|
pubmed:dateRevised |
2007-12-3
|
pubmed:meshHeading |
pubmed-meshheading:17036780-Biomedical Research,
pubmed-meshheading:17036780-Equipment Design,
pubmed-meshheading:17036780-Equipment Failure Analysis,
pubmed-meshheading:17036780-Image Enhancement,
pubmed-meshheading:17036780-Image Interpretation, Computer-Assisted,
pubmed-meshheading:17036780-Phantoms, Imaging,
pubmed-meshheading:17036780-Reproducibility of Results,
pubmed-meshheading:17036780-Sensitivity and Specificity,
pubmed-meshheading:17036780-Signal Processing, Computer-Assisted,
pubmed-meshheading:17036780-Systems Integration,
pubmed-meshheading:17036780-Transducers,
pubmed-meshheading:17036780-Ultrasonography
|
pubmed:year |
2006
|
pubmed:articleTitle |
A ring transducer system for medical ultrasound research.
|
pubmed:affiliation |
Department of Electrical and Computer Engineering and Imaging Sciences, University of Rochester, Rochester, NY 14627, USA. waag@ece.rochester.edu
|
pubmed:publicationType |
Journal Article,
Research Support, Non-U.S. Gov't,
Evaluation Studies,
Research Support, N.I.H., Extramural
|