Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
11
pubmed:dateCreated
2006-1-20
pubmed:abstractText
Ultrasound contrast agents enhance echoes from the microvasculature and enable the visualization of flow in smaller vessels. Here, we optically and acoustically investigate microbubble oscillation and echoes following insonation with a 10 MHz center frequency pulse. A high-speed camera system with a temporal resolution of 10 ns, which provides two-dimensional (2-D) frame images and streak images, is used in optical experiments. Two confocally aligned transducers, transmitting at 10 MHz and receiving at 5 MHz, are used in acoustical experiments in order to detect subharmonic components. Results of a numerical evaluation of the modified Rayleigh-Plesset equation are used to predict the dynamics of a microbubble and are compared to results of in vitro experiments. From the optical observations of a single microbubble, nonlinear oscillation, destruction, and radiation force are observed. The maximum bubble expansion, resulting from insonation with a 20-cycle, 10-MHz linear chirp with a peak negative pressure of 3.5 MPa, has been evaluated. For an initial diameter ranging from 1.5 to 5 microm, a maximum diameter less than 8 microm is produced during insonation. Optical and acoustical experiments provide insight into the mechanisms of destruction, including fragmentation and active diffusion. High-frequency pulse transmission may provide the opportunity to detect contrast echoes resulting from a single pulse, may be robust in the presence of tissue motion, and may provide the opportunity to incorporate high-frequency ultrasound into destruction-replenishment techniques.
pubmed:grant
pubmed:commentsCorrections
http://linkedlifedata.com/resource/pubmed/commentcorrection/16422410-10211802, http://linkedlifedata.com/resource/pubmed/commentcorrection/16422410-10320317, http://linkedlifedata.com/resource/pubmed/commentcorrection/16422410-10374986, http://linkedlifedata.com/resource/pubmed/commentcorrection/16422410-10530033, http://linkedlifedata.com/resource/pubmed/commentcorrection/16422410-10722920, http://linkedlifedata.com/resource/pubmed/commentcorrection/16422410-10773381, http://linkedlifedata.com/resource/pubmed/commentcorrection/16422410-10829636, http://linkedlifedata.com/resource/pubmed/commentcorrection/16422410-10996696, http://linkedlifedata.com/resource/pubmed/commentcorrection/16422410-12113791, http://linkedlifedata.com/resource/pubmed/commentcorrection/16422410-12113792, http://linkedlifedata.com/resource/pubmed/commentcorrection/16422410-12604116, http://linkedlifedata.com/resource/pubmed/commentcorrection/16422410-12659915, http://linkedlifedata.com/resource/pubmed/commentcorrection/16422410-14526091, http://linkedlifedata.com/resource/pubmed/commentcorrection/16422410-14553812, http://linkedlifedata.com/resource/pubmed/commentcorrection/16422410-14698342, http://linkedlifedata.com/resource/pubmed/commentcorrection/16422410-14998672, http://linkedlifedata.com/resource/pubmed/commentcorrection/16422410-15478411, http://linkedlifedata.com/resource/pubmed/commentcorrection/16422410-8849831, http://linkedlifedata.com/resource/pubmed/commentcorrection/16422410-9587994
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Nov
pubmed:issn
0885-3010
pubmed:author
pubmed:issnType
Print
pubmed:volume
52
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
1981-91
pubmed:dateRevised
2010-12-3
pubmed:meshHeading
pubmed:year
2005
pubmed:articleTitle
High-frequency dynamics of ultrasound contrast agents.
pubmed:affiliation
UC Davis, Davis, CA 95616, USA. ywsun@ucdavis.edu
pubmed:publicationType
Journal Article, Research Support, N.I.H., Extramural