2005-11-10
|
pubmed:abstractText |
To determine if the improved contrast resolution of full-field digital mammography (FFDM) with reduced spatial resolution allows for superior or equal phantom object detection compared with screen-film mammography (SFM). Tissue equivalent breast phantoms simulating an adipose to glandular ratio of 50/50,30/70, and 20/80 were imaged according to each manufacturers' recommendation with four full-field digital mammography units (Fuji, Sectra, Fischer, and General Electric) and a screen-film mammography unit (MammoMatII 2000, Siemens, Munich, Germany). A total of 20 images were obtained in both hard- and soft-copy formats. For the purpose of soft-copy display, the screen-film hard-copy images were digitized with a 50 microm micron scanner. Six radiologists, experts in breast imaging, and three physicists, experts in scoring mammography phantoms, participated in a reader study where each reader scored each phantom for visibility of line-pairs and for 24 objects (fibers, clusters of specks, and masses). The data were recorded, entered into a database, and analyzed by a mixed-effect model. The limiting spatial resolution in line-pairs per millimeter visible with the digital units was less, regardless of display modality used, than that provided by the screen-film unit. The difference was statistically significant for the General Electric (p < 0.01) and Fuji digital mammography units (p = 0.03). With respect to the number of visible objects, a statistically significant higher number could be detected with the screen-film unit as compared to the Fischer (p < 0.01) and Sectra (p < 0.01) digital mammography units, but there was no significant difference between the other digital units and screen film. Overall, there was significantly better performance on the 50/50 phantom than with the 30/70 and 20/80 phantoms (p = 0.01, p < 0.01) for object visibility. For the digital mammography units, soft-copy display performed better than hard-copy display for the Fischer and Sectra images, but worse for Fuji and General Electric. In addition, soft-copy display of digitized screen-film images was significantly better than hard-copy display (p =0.02) of the original screen films for object visibility, but worse for spatial resolution. The higher contrast resolution of the FFDM units tested did not result in improved detection of line-pair resolution or objects in the phantoms tested versus screen-film mammography. The phantom performance of a digital mammography unit seems to be influenced by the type of detection task (line-pair resolution versus object visibility), the display modality (soft-copy versus hard-copy) chosen to score the phantoms, and the parenchymal pattern composition of the phantom.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Oct
|
pubmed:issn |
0094-2405
|
pubmed:author |
pubmed-author:BurnsCharles BCB,
pubmed-author:ColeElodia BEB,
pubmed-author:KoomenMarciaM,
pubmed-author:KuzmiakCherie MCM,
pubmed-author:LeeYeonheeY,
pubmed-author:PavicDagD,
pubmed-author:PisanoEtta DED,
pubmed-author:RobertoCraigC,
pubmed-author:SeoBo KyoungBK,
pubmed-author:WashburnDavidD,
pubmed-author:ZengDonglinD
|
pubmed:issnType |
Print
|
pubmed:volume |
32
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
3144-50
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading |
pubmed-meshheading:16279068-Breast Neoplasms,
pubmed-meshheading:16279068-Equipment Failure Analysis,
pubmed-meshheading:16279068-Mammography,
pubmed-meshheading:16279068-Phantoms, Imaging,
pubmed-meshheading:16279068-Radiographic Image Enhancement,
pubmed-meshheading:16279068-Radiographic Image Interpretation, Computer-Assisted,
pubmed-meshheading:16279068-Reproducibility of Results,
pubmed-meshheading:16279068-Sensitivity and Specificity,
pubmed-meshheading:16279068-X-Ray Intensifying Screens
|
pubmed:year |
2005
|
pubmed:articleTitle |
Comparison of full-field digital mammography to screen-film mammography with respect to contrast and spatial resolution in tissue equivalent breast phantoms.
|
pubmed:affiliation |
Department of Radiology, University of North Carolina at Chapel Hill, Old Infirmary Builiding, Room 513, CB#7510, Chapel Hill, North Carolina 27599, USA.
|
pubmed:publicationType |
Journal Article,
Comparative Study,
Evaluation Studies
|