pubmed:abstractText
A recent study demonstrated that the incidence of new arrhythmias occurring during central venous catheter insertion or exchange was 41% atrial and 25% ventricular arrhythmias (12% couplets or greater). Over-insertion of the guidewire, causing direct stimulation to the right side of the heart, has been postulated to be the causative factor. A new technique that allows the operator to control the length of guidewire inserted was developed. With this technique on a population of hospitalized patients, similar to those in the previous study, the incidence of atrial arrhythmias decreased to 32% and the incidence of ventricular arrhythmias to 6% (single premature ventricular contractions only). Although this new technique has limitations, there was a dramatic improvement in the incidence of cardiac arrhythmias. These results indicate a need for modifications in the available equipment to avoid the infrequent but life-threatening complication of malignant arrhythmia.
pubmed:commentsCorrections
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:issn
0899-9007
pubmed:author
pubmed:issnType
Print
pubmed:volume
8
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
19-21
pubmed:dateRevised
2007-11-15
pubmed:meshHeading
pubmed:articleTitle
Reducing arrhythmias associated with central venous catheter insertion or exchange.
pubmed:affiliation
New England Deaconess Hospital, Harvard Medical School, Boston, Massachusetts.
pubmed:publicationType
Journal Article