Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
21
pubmed:dateCreated
2003-10-31
pubmed:abstractText
Although several designs have been advanced for coupling sample enrichment devices to a sheathless electrospray ionization-mass spectrometry (MS) interface on a capillary electrophoresis (CE) column, most of these approaches suffer from difficulties in fabrication, and the CE separation efficiency is degraded as a result of the presence of coupling sleeves. We have developed a design that offers significant improvements in terms of ease of fabrication, durability, and maintenance of the integrity of the CE-separated analyte zones. Capillaries with different inside and outside diameters were evaluated to optimize the performance of the CE-MS system, resulting in a mass limit of detection of 500 amol for tandem MS analysis of a standard peptide using a 20-microm-i.d. capillary. The improved design incorporates an efficient method to preconcentrate a sample directly within the CE capillary followed by its electrophoretic separation and detection using a true zero dead-volume sheathless CE-MS interface. Testing of this novel CE-MS system showed its ability to characterize proteomic samples such as protein digests, in-gel-digested proteins, and hydrophobic peptides as well as to quantitate ICAT-labeled peptides.
pubmed:grant
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
http://linkedlifedata.com/resource/pubmed/chemical/Apoproteins, http://linkedlifedata.com/resource/pubmed/chemical/Bacteriorhodopsins, http://linkedlifedata.com/resource/pubmed/chemical/Cytochromes c, http://linkedlifedata.com/resource/pubmed/chemical/Fibrinopeptide B, http://linkedlifedata.com/resource/pubmed/chemical/Hydrofluoric Acid, http://linkedlifedata.com/resource/pubmed/chemical/Myoglobin, http://linkedlifedata.com/resource/pubmed/chemical/Peptide Fragments, http://linkedlifedata.com/resource/pubmed/chemical/Peptides, http://linkedlifedata.com/resource/pubmed/chemical/Proteins, http://linkedlifedata.com/resource/pubmed/chemical/Serum Albumin, http://linkedlifedata.com/resource/pubmed/chemical/Silicon Dioxide, http://linkedlifedata.com/resource/pubmed/chemical/Trypsin, http://linkedlifedata.com/resource/pubmed/chemical/apomyoglobin
pubmed:status
MEDLINE
pubmed:month
Nov
pubmed:issn
0003-2700
pubmed:author
pubmed:issnType
Print
pubmed:day
1
pubmed:volume
75
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
5984-93
pubmed:dateRevised
2010-11-18
pubmed:meshHeading
pubmed-meshheading:14588041-Amino Acid Sequence, pubmed-meshheading:14588041-Apoproteins, pubmed-meshheading:14588041-Bacteriorhodopsins, pubmed-meshheading:14588041-Cytochromes c, pubmed-meshheading:14588041-Electrophoresis, Capillary, pubmed-meshheading:14588041-Fibrinopeptide B, pubmed-meshheading:14588041-Hydrofluoric Acid, pubmed-meshheading:14588041-Hydrophobic and Hydrophilic Interactions, pubmed-meshheading:14588041-Isotope Labeling, pubmed-meshheading:14588041-Microscopy, Electron, Scanning, pubmed-meshheading:14588041-Molecular Sequence Data, pubmed-meshheading:14588041-Molecular Weight, pubmed-meshheading:14588041-Myoglobin, pubmed-meshheading:14588041-Peptide Fragments, pubmed-meshheading:14588041-Peptides, pubmed-meshheading:14588041-Proteins, pubmed-meshheading:14588041-Serum Albumin, pubmed-meshheading:14588041-Silicon Dioxide, pubmed-meshheading:14588041-Spectrometry, Mass, Electrospray Ionization, pubmed-meshheading:14588041-Trypsin
pubmed:year
2003
pubmed:articleTitle
On-column sample enrichment for capillary electrophoresis sheathless electrospray ionization mass spectrometry: evaluation for peptide analysis and protein identification.
pubmed:affiliation
Laboratory of Proteomics and Analytical Technologies and Image Analysis Laboratory, SAIC-Frederick, Inc., National Cancer Institute at Frederick, P.O. Box B, Frederick, Maryland 21702, USA. Janini@mail.ncifcrf.gov
pubmed:publicationType
Journal Article, Research Support, U.S. Gov't, P.H.S.