pubmed:abstractText |
The objectives of this study were to determine whether three-dimensional ultrasonography can provide more cardiac views than two-dimensional ultrasonography and to develop a standard technique. Eighteen women, 16 to 26 weeks' gestation, were scanned with two-dimensional ultrasonography for 10 minutes or less to obtain fetal heart views. Three-dimensional ultrasonography was used (< or =10 minutes) to obtain up to 4 acquisitions of the fetal heart: 4-chamber view, left parasagittal, transverse, and longitudinal nonstandard. Views were later extracted from saved volume data, comparing the yields of two- and three-dimensional ultrasonography. The 4-chamber view was obtained in 15 (93%) of 16 cases on both two- and three-dimensional ultrasonography. On two-dimensional ultrasonography, the left outflow tract was obtained in 68% of the cases; on three-dimensional ultrasonography, the left outflow tract was obtained in 46% from the 4-chamber view acquisition and in 100% from the left parasagittal acquisition. On two-dimensional ultrasonography, the right outflow tract was obtained in 68% of the cases; on three-dimensional ultrasonography, the right outflow tract was obtained in 86% from the 4-chamber view acquisition and in 71% from the left parasagittal acquisition. Aortic and ductal arches were obtained in 12% and 18%, respectively, on two-dimensional ultrasonography. On three-dimensional ultrasonography the aortic and ductal arches were obtained in 66% and 86%, respectively, from the 4-chamber view acquisition and in 57% and 71%, respectively, from the left parasagittal acquisition. Three-dimensional ultrasonography permitted a greater number of cardiac views to be extracted from volume data than did two-dimensional ultrasonography.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Apr
|
pubmed:issn |
0278-4297
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
20
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
307-13; quiz 315-6
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading | |
pubmed:year |
2001
|
pubmed:articleTitle |
Application of three-dimensional ultrasonography in the evaluation of the fetal heart.
|
pubmed:affiliation |
Department of Radiology, Jefferson Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania, USA.
|
pubmed:publicationType |
Journal Article,
Comparative Study
|