Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:9519477rdf:typepubmed:Citationlld:pubmed
pubmed-article:9519477lifeskim:mentionsumls-concept:C0086418lld:lifeskim
pubmed-article:9519477lifeskim:mentionsumls-concept:C0678133lld:lifeskim
pubmed-article:9519477lifeskim:mentionsumls-concept:C0032105lld:lifeskim
pubmed-article:9519477lifeskim:mentionsumls-concept:C2347026lld:lifeskim
pubmed-article:9519477lifeskim:mentionsumls-concept:C0370003lld:lifeskim
pubmed-article:9519477lifeskim:mentionsumls-concept:C0144576lld:lifeskim
pubmed-article:9519477lifeskim:mentionsumls-concept:C0184661lld:lifeskim
pubmed-article:9519477lifeskim:mentionsumls-concept:C0680730lld:lifeskim
pubmed-article:9519477lifeskim:mentionsumls-concept:C0205554lld:lifeskim
pubmed-article:9519477lifeskim:mentionsumls-concept:C1521827lld:lifeskim
pubmed-article:9519477lifeskim:mentionsumls-concept:C0599748lld:lifeskim
pubmed-article:9519477lifeskim:mentionsumls-concept:C1148554lld:lifeskim
pubmed-article:9519477lifeskim:mentionsumls-concept:C0008565lld:lifeskim
pubmed-article:9519477lifeskim:mentionsumls-concept:C1720880lld:lifeskim
pubmed-article:9519477lifeskim:mentionsumls-concept:C0392762lld:lifeskim
pubmed-article:9519477pubmed:issue5lld:pubmed
pubmed-article:9519477pubmed:dateCreated1998-4-23lld:pubmed
pubmed-article:9519477pubmed:abstractTextA sensitive, specific, accurate and reproducible analytical method was developed and validated for the quantitation of the anticancer agent paclitaxel in human plasma. This procedure is based on high performance liquid chromatography/ion spray-tandem mass spectrometry. This methodology is highly specific because a MS/MS technique (multiple reactant-ion monitoring, MRM) was used for both paclitaxel and its internal standard. The use of a fully automated solid phase extraction procedure, using a CN Sep-pak cartridge, to improve the detection limit and quantification limit of paclitaxel in human plasma samples, was evaluated. The method involves the addition of methyl-paclitaxel as internal standard (i.s.). The retention times of paclitaxel and the I.S. were 2.8 and 4.0 min., respectively. The assay was linear over the range 5 to 500 ng/mL, with a quantification limit of 5 ng/mL having a coefficient of variation (c.v.) < 10%. Standard calibration curves, performed on three different days, had correlation coefficients always greater than 0.998. The intra and inter-day precision were within 12%, and accuracy was included in the range 102-110%. Paclitaxel recovery assessed at 15,250 and 500 ng/mL, was determined to be greater than 85%. The assay is applicable to clinical pharmacokinetic studies.lld:pubmed
pubmed-article:9519477pubmed:languageenglld:pubmed
pubmed-article:9519477pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:9519477pubmed:citationSubsetIMlld:pubmed
pubmed-article:9519477pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:9519477pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:9519477pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:9519477pubmed:statusMEDLINElld:pubmed
pubmed-article:9519477pubmed:issn0951-4198lld:pubmed
pubmed-article:9519477pubmed:authorpubmed-author:MinoiaCClld:pubmed
pubmed-article:9519477pubmed:authorpubmed-author:ZucchettiMMlld:pubmed
pubmed-article:9519477pubmed:authorpubmed-author:D'IncalciMMlld:pubmed
pubmed-article:9519477pubmed:authorpubmed-author:PaganiniMMlld:pubmed
pubmed-article:9519477pubmed:authorpubmed-author:SottaniCClld:pubmed
pubmed-article:9519477pubmed:issnTypePrintlld:pubmed
pubmed-article:9519477pubmed:volume12lld:pubmed
pubmed-article:9519477pubmed:ownerNLMlld:pubmed
pubmed-article:9519477pubmed:authorsCompleteYlld:pubmed
pubmed-article:9519477pubmed:pagination251-5lld:pubmed
pubmed-article:9519477pubmed:dateRevised2006-11-15lld:pubmed
pubmed-article:9519477pubmed:meshHeadingpubmed-meshheading:9519477-...lld:pubmed
pubmed-article:9519477pubmed:meshHeadingpubmed-meshheading:9519477-...lld:pubmed
pubmed-article:9519477pubmed:meshHeadingpubmed-meshheading:9519477-...lld:pubmed
pubmed-article:9519477pubmed:meshHeadingpubmed-meshheading:9519477-...lld:pubmed
pubmed-article:9519477pubmed:meshHeadingpubmed-meshheading:9519477-...lld:pubmed
pubmed-article:9519477pubmed:meshHeadingpubmed-meshheading:9519477-...lld:pubmed
pubmed-article:9519477pubmed:meshHeadingpubmed-meshheading:9519477-...lld:pubmed
pubmed-article:9519477pubmed:year1998lld:pubmed
pubmed-article:9519477pubmed:articleTitleHigh-performance liquid chromatography tandem mass spectrometry procedure with automated solid phase extraction sample preparation for the quantitative determination of paclitaxel (Taxol) in human plasma.lld:pubmed
pubmed-article:9519477pubmed:affiliationLaboratory of Environmental Hygiene and Industrial Toxicology, S. Maugeri Foundation, Pavia, Italy.lld:pubmed
pubmed-article:9519477pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:9519477pubmed:publicationTypeClinical Triallld:pubmed