Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
2
pubmed:dateCreated
1994-4-14
pubmed:abstractText
We describe a new indicator dilution method of measuring cardiac output in man. A bolus injection of lithium chloride 0.6 mmol was given via a central venous catheter and arterial plasma [Li+] recorded using a specially developed sensor incorporating an Li(+)-selective electrode. Cardiac output was derived from the lithium dilution curve, with a correction for packed cell volume. Lithium dilution cardiac output (LiDCO) was compared with thermodilution cardiac output (TD) using 22 lithium sensors in nine patients. For each sensor, one LiDCO was measured immediately before and one immediately after three TD estimations and mean values of LiDCO and TD derived. The correlation coefficient, r, was 0.89; slope of the regression 0.84; y intercept 0.72; bias 0.3 (0.5) litre min-1 (mean (TD-LiDCO) (1 SD). LiDCO appeared to be a safe, simple and accurate technique which does not require insertion of a pulmonary artery catheter.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Aug
pubmed:issn
0007-0912
pubmed:author
pubmed:issnType
Print
pubmed:volume
71
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
262-6
pubmed:dateRevised
2004-11-17
pubmed:meshHeading
pubmed:year
1993
pubmed:articleTitle
A new method of measuring cardiac output in man using lithium dilution.
pubmed:affiliation
Department of Anaesthetics, St Thomas's Hospital, London.
pubmed:publicationType