Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
4
|
pubmed:dateCreated |
1994-8-23
|
pubmed:abstractText |
This study compared the adequacy of office endometrial biopsies taken with the Novak curette and a disposable, flexible polypropylene biopsy device, the Z-sampler, in premenopausal and postmenopausal women. Between September 1988 and November 1991, 407 women had paired office endometrial biopsies with the Z-sampler followed by the Novak curette. Overall, 83.0% of endometrial biopsies obtained with the Z-sampler were adequate for histopathologic diagnosis as compared to 84.5% obtained with the Novak curette (P = .53). In 181 (44.5%) premenopausal women, 94.5% of Z-sampler biopsies were adequate as compared to 95.6% of Novak curette biopsies (P = .80). In 226 (55.6%) post-menopausal women, 73.9% of Z-sampler biopsies were adequate as compared to 75.7% of Novak curette biopsies (P = .66). The Z-sampler biopsies were adequate in 94.5% of premenopausal women as compared to 73.9% of postmenopausal women (P < .0001). The Novak curette biopsies were adequate in 95.6% of premenopausal women as compared to 75.7% of post-menopausal women (P < .001). While we did not demonstrate a significant difference in the adequacy of endometrial samples taken with the Z-sampler and Novak curette in premenopausal and postmenopausal women, postmenopausal women had a significantly lower rate of adequate samples obtained with either device as compared to premenopausal women.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Apr
|
pubmed:issn |
0024-7758
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
39
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
300-3
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading |
pubmed-meshheading:8040848-Adult,
pubmed-meshheading:8040848-Aged,
pubmed-meshheading:8040848-Aged, 80 and over,
pubmed-meshheading:8040848-Ambulatory Surgical Procedures,
pubmed-meshheading:8040848-Biopsy,
pubmed-meshheading:8040848-Endometrium,
pubmed-meshheading:8040848-Female,
pubmed-meshheading:8040848-Humans,
pubmed-meshheading:8040848-Middle Aged,
pubmed-meshheading:8040848-Postmenopause,
pubmed-meshheading:8040848-Premenopause,
pubmed-meshheading:8040848-Vacuum Curettage
|
pubmed:year |
1994
|
pubmed:articleTitle |
Histopathologic adequacy of office endometrial biopsies taken with the Z-sampler and Novak curette in premenopausal and postmenopausal women.
|
pubmed:affiliation |
Department of Obstetrics and Gynecology, Marshfield Clinic, WI 54449-5777.
|
pubmed:publicationType |
Journal Article,
Comparative Study
|