pubmed:abstractText |
A plasma assay for paracetamol by HPLC is described. Paracetamol is extracted with diethyl ether in the presence of an internal standard, beta- hydroxyethyltheophylline . The extracts are analysed using reversed phase chromatography (Radial Pak C18 column), the mobile phase consisting of a buffer mixture of 0.01 mol/l acetate (pH 4)-acetonitrile (920-80, v/v). The method is simple, rapid, precise and sensitive (lower level of sensitivity 0.13 mumol/l). It was used in a pharmacokinetic study in twelve volunteers.
|
pubmed:language |
fre
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:issn |
0003-3898
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
42
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
9-13
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading | |
pubmed:year |
1984
|
pubmed:articleTitle |
[Plasma determination of paracetamol using high performance liquid chromatography. Application to a pharmacokinetic study].
|
pubmed:publicationType |
Journal Article,
English Abstract
|