Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
2
|
pubmed:dateCreated |
1985-2-4
|
pubmed:abstractText |
A selective and convenient high-performance liquid chromatographic assay was developed for ethylenediamineplatinum(II) malonate (JM-40) in plasma ultrafiltrate and urine. A mu Porasil silica column (30 cm) was used with acetonitrile-water (90:10, v/v) as the mobile phase and the elution of compounds was monitored by ultraviolet absorbance at 214 nm. A linear dynamic range of at least three decades (1-1000 micrograms/ml) was achieved. The detection limit in plasma ultrafiltrate was 0.35 micrograms/ml. The stability of JM-40 was determined in 0.9% sodium chloride, 5% glucose, plasma ultrafiltrate and urine. More stable drug solutions were obtained with 5% glucose than with 0.9% sodium chloride. JM-40 was also determined in plasma ultrafiltrate and urine samples of one patient receiving short-term infusions of the drug. In plasma ultrafiltrate unmetabolized JM-40 was detected during the first 5 h after administration and had a half-life of 21.3 +/- 1.6 min. The parent drug was excreted in the urine in rapidly decreasing amounts. Eighteen per cent of the dose was recovered as unmetabolized drug during the first 6 h.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical |
http://linkedlifedata.com/resource/pubmed/chemical/Antineoplastic Agents,
http://linkedlifedata.com/resource/pubmed/chemical/Organoplatinum Compounds,
http://linkedlifedata.com/resource/pubmed/chemical/Platinum,
http://linkedlifedata.com/resource/pubmed/chemical/Solutions,
http://linkedlifedata.com/resource/pubmed/chemical/ethylenediamine platinum(II)...
|
pubmed:status |
MEDLINE
|
pubmed:month |
Oct
|
pubmed:issn |
0021-9673
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:day |
12
|
pubmed:volume |
310
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
335-42
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading |
pubmed-meshheading:6511851-Antineoplastic Agents,
pubmed-meshheading:6511851-Chromatography, High Pressure Liquid,
pubmed-meshheading:6511851-Drug Stability,
pubmed-meshheading:6511851-Humans,
pubmed-meshheading:6511851-Infusions, Parenteral,
pubmed-meshheading:6511851-Kinetics,
pubmed-meshheading:6511851-Organoplatinum Compounds,
pubmed-meshheading:6511851-Platinum,
pubmed-meshheading:6511851-Solutions,
pubmed-meshheading:6511851-Spectrophotometry, Ultraviolet,
pubmed-meshheading:6511851-Time Factors
|
pubmed:year |
1984
|
pubmed:articleTitle |
Determination of ethylenediamineplatinum(II) malonate in infusion fluids, human plasma and urine by high-performance liquid chromatography.
|
pubmed:publicationType |
Journal Article,
Research Support, Non-U.S. Gov't
|