Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
3
pubmed:dateCreated
1974-6-26
pubmed:abstractText
1. A voltage-clamp technique for the measurement of effective membrane capacity is described and its theoretical basis given in an Appendix. Unlike most other methods used so far, the present technique does not depend on the assumption of a particular equivalent circuit for muscle membrane.2. With this technique, we have re-examined the effect of media of low ion content on the effective membrane capacity C(eff). In fibres where potassium conductance is blocked by Rb, C(eff) failed to show any appreciable dependence on ionic strength (between 0.015 and 0.29 M) or conductivity (between 0.86 and 13.4 mmho/cm) of the bathing medium.3. Low conductivity can reduce C(eff) in fibres of moderately high K-conductance. However, in all cases explored here, C(eff) had values well above the 2 muF/cm(2) found in glycerol-treated fibres, indicating that passive spread of potential displacements from surface into the tubular system could still occur.4. The changes in C(eff) observed under conditions of moderately high K-conductance are explicable as a result of potential decrements in the transverse tubules, which would be expected when the wall conductance there is high, and the conductivity of the tubule lumen is low.
pubmed:commentsCorrections
http://linkedlifedata.com/resource/pubmed/commentcorrection/4545185-13368111, http://linkedlifedata.com/resource/pubmed/commentcorrection/4545185-13714851, http://linkedlifedata.com/resource/pubmed/commentcorrection/4545185-14142170, http://linkedlifedata.com/resource/pubmed/commentcorrection/4545185-14898516, http://linkedlifedata.com/resource/pubmed/commentcorrection/4545185-4512014, http://linkedlifedata.com/resource/pubmed/commentcorrection/4545185-4536730, http://linkedlifedata.com/resource/pubmed/commentcorrection/4545185-4536963, http://linkedlifedata.com/resource/pubmed/commentcorrection/4545185-4540479, http://linkedlifedata.com/resource/pubmed/commentcorrection/4545185-4547276, http://linkedlifedata.com/resource/pubmed/commentcorrection/4545185-4556582, http://linkedlifedata.com/resource/pubmed/commentcorrection/4545185-4679725, http://linkedlifedata.com/resource/pubmed/commentcorrection/4545185-5016975, http://linkedlifedata.com/resource/pubmed/commentcorrection/4545185-5058964, http://linkedlifedata.com/resource/pubmed/commentcorrection/4545185-5352046, http://linkedlifedata.com/resource/pubmed/commentcorrection/4545185-5352048, http://linkedlifedata.com/resource/pubmed/commentcorrection/4545185-5475999, http://linkedlifedata.com/resource/pubmed/commentcorrection/4545185-5767332, http://linkedlifedata.com/resource/pubmed/commentcorrection/4545185-5767333, http://linkedlifedata.com/resource/pubmed/commentcorrection/4545185-5796367, http://linkedlifedata.com/resource/pubmed/commentcorrection/4545185-5840799, http://linkedlifedata.com/resource/pubmed/commentcorrection/4545185-6063689
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Mar
pubmed:issn
0022-3751
pubmed:author
pubmed:issnType
Print
pubmed:volume
237
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
573-605
pubmed:dateRevised
2009-11-18
pubmed:meshHeading
pubmed:year
1974
pubmed:articleTitle
Membrane capacity measurements on frog skeletal muscle in media of low ion content.
pubmed:publicationType
Journal Article, In Vitro