Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
2
pubmed:dateCreated
1979-6-29
pubmed:abstractText
Immunofluorescent staining of Treponema pallidum was studied to clarify the effect of three factors on the results of the fluorescent treponemal antibody-absorption test: (i) heat inactivation of sera at 56 degrees C for 30 min before testing, (ii) use of multicircle slides, and (iii) tungsten illumination to visualize and assess unstained treponemes on reactive as well as nonreactive smears. It was found that serum inactivation before testing was not necessary for detection of immunoglobin G antibody, but an immunoglobulin M prozone was detected in unheated serum. On multicircle slides, it was demonstrated that a false-positive reaction could be obtained in 30 s at 37 and 25 degrees C if a smear where a nonreactive serum had been placed was crossed by a strongly reactive serum from another circle. Tungsten illumination proved necessary for correct assessment of unstained treponemes on all fluorescent treponemal antibody-aborption test smears, reactive or nonreactive. The possible role of these factors in incorrect fluorescent treponemal antibody-absorption test results is discussed.
pubmed:commentsCorrections
http://linkedlifedata.com/resource/pubmed/commentcorrection/372219-1100871, http://linkedlifedata.com/resource/pubmed/commentcorrection/372219-1101788, http://linkedlifedata.com/resource/pubmed/commentcorrection/372219-1104227, http://linkedlifedata.com/resource/pubmed/commentcorrection/372219-1107411, http://linkedlifedata.com/resource/pubmed/commentcorrection/372219-4190042, http://linkedlifedata.com/resource/pubmed/commentcorrection/372219-4212719, http://linkedlifedata.com/resource/pubmed/commentcorrection/372219-4555838, http://linkedlifedata.com/resource/pubmed/commentcorrection/372219-4564403, http://linkedlifedata.com/resource/pubmed/commentcorrection/372219-4608796, http://linkedlifedata.com/resource/pubmed/commentcorrection/372219-4885811, http://linkedlifedata.com/resource/pubmed/commentcorrection/372219-4896635, http://linkedlifedata.com/resource/pubmed/commentcorrection/372219-4917188, http://linkedlifedata.com/resource/pubmed/commentcorrection/372219-4919012, http://linkedlifedata.com/resource/pubmed/commentcorrection/372219-4959911, http://linkedlifedata.com/resource/pubmed/commentcorrection/372219-4976968, http://linkedlifedata.com/resource/pubmed/commentcorrection/372219-5332304, http://linkedlifedata.com/resource/pubmed/commentcorrection/372219-789394
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Feb
pubmed:issn
0095-1137
pubmed:author
pubmed:issnType
Print
pubmed:volume
9
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
163-6
pubmed:dateRevised
2009-11-18
pubmed:meshHeading
pubmed:year
1979
pubmed:articleTitle
Problems affecting performance of the fluorescent treponemal antibody-absorption test for syphilis.
pubmed:publicationType
Journal Article, Comparative Study