pubmed:abstractText |
Although graft dimension and hemodynamic variables have been suggested as important determinants of the functional results of aortocoronary bypass grafting, there is no easy-to-use bedside method of monitoring phasic blood flow in coronary bypass grafts. We developed a miniaturized implantable silicone pulsed Doppler flow probe linked to a classic 8 MHz pulsed Doppler system. This apparatus has an adjustable range-gated time system that permits accurate measurement of diameter (D, in mm), cross-sectional blood flow velocity (Vm, in cm/sec), and coronary bypass graft flow (CBGF, in ml/min) as pi D2/4 X Vm X 60. Ten patients (55 +/- 7.2 years SD) with preoperative left ventricular ejection fractions over 45% received the implantable flow probes during the aortocoronary venous bypass procedure. Closure of the chest altered systolic and diastolic components of flow velocity and CBGF decreased from 131 +/- 65.8 to 94 +/- 55 ml/min (-28%; p less than .01). Comparison between early postoperative values (intensive care unit) and values 6 days later showed significant increases in diameter from 4.2 +/- 0.9 to 5.3 +/- 0.9 mm (p less than .01) and in CBGF from 130 +/- 112 to 204 +/- 86 ml/min (p less than .01). We conclude that the implantable pulsed Doppler microprobe is a sensitive bedside method for monitoring aortocoronary bypass graft diameter and blood flow in the postoperative period.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
AIM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Nov
|
pubmed:issn |
0009-7322
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
74
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
III61-7
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading |
pubmed-meshheading:3490333-Blood Flow Velocity,
pubmed-meshheading:3490333-Coronary Artery Bypass,
pubmed-meshheading:3490333-Echocardiography,
pubmed-meshheading:3490333-Electrodes, Implanted,
pubmed-meshheading:3490333-Humans,
pubmed-meshheading:3490333-Intraoperative Period,
pubmed-meshheading:3490333-Microelectrodes,
pubmed-meshheading:3490333-Middle Aged,
pubmed-meshheading:3490333-Postoperative Period,
pubmed-meshheading:3490333-Saphenous Vein
|
pubmed:year |
1986
|
pubmed:articleTitle |
Comparison of perioperative and postoperative phasic blood flow in aortocoronary venous bypass grafts by means of pulsed Doppler echocardiography with implantable microprobes.
|
pubmed:publicationType |
Journal Article,
Comparative Study,
Research Support, Non-U.S. Gov't
|