Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
4
pubmed:dateCreated
1988-10-11
pubmed:abstractText
This study analyses 75 membrane plasma exchanges carried out in 18 patients where various amounts of heparin were used to define the heparin kinetic during plasma exchange and the appropriate anticoagulation. A specific assay was employed to measure heparin concentration. Our results showed that: 1) the heparin distribution volume exceeded the expected value by 10 to 25%; 2) the drug is filtered with a sieving coefficient = 1; 3) the appropriate concentration range is within 0.2 and 0.5 Ul/ml.; 4) the heparin blood levels strictly correlate with a PTT (p less than 0.001); 5) the individual need for heparin is related to the patient Hct (p less than 0.001) and plasma flow (p less than 0.001). Simple guidelines are provided to determine the appropriate heparin dosage in single patients.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Jul
pubmed:issn
0391-3988
pubmed:author
pubmed:issnType
Print
pubmed:volume
11
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
313-6
pubmed:dateRevised
2004-11-17
pubmed:meshHeading
pubmed:year
1988
pubmed:articleTitle
Optimization of heparin anticoagulation during membrane plasma separation.
pubmed:affiliation
Institute of Nephrology, St. Orsola Univ. Hospital, Bologna-Italy.
pubmed:publicationType