Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
1
pubmed:dateCreated
1989-9-8
pubmed:abstractText
We describe a case of percutaneous balloon valvoplasty of a stenotic Hancock bioprosthesis in aortic position. The procedure reduced the peak systolic gradient from 110 to 25 mm Hg. The calculated area of the orifice increased from 0.59 to 1.07 cm2. A cineaortogram performed after the procedure showed trivial aortic regurgitation and the subsequent immediate course was uneventful. The mechanism of dilatation and the risks of the procedure are discussed.