pubmed:abstractText
Precise and convenient crystal reorientation is of experimental importance in macromolecular crystallography (MX). The development of multi-axis goniometers, such as the ESRF/EMBL mini-?, necessitates the corresponding development of calibration procedures that can be used for the setup, maintenance and troubleshooting of such devices. While traditional multi-axis goniometers require all rotation axes to intersect the unique point of the sample position, recently developed miniaturized instruments for sample reorientation in MX are not as restricted. However, the samples must always be re-centred following a change in orientation. To overcome this inconvenience and allow the use of multi-axis goniometers without the fundamental restriction of having all axes intersecting in the same point, an automatic translation correction protocol has been developed for such instruments. It requires precise information about the direction and location of the rotation axes. To measure and supply this information, a general, easy-to-perform translation calibration (TC) procedure has also been developed. The TC procedure is routinely performed on most MX beamlines at the ESRF and some results are presented for reference.
pubmed:commentsCorrections
http://linkedlifedata.com/resource/pubmed/commentcorrection/21487180-10531520, http://linkedlifedata.com/resource/pubmed/commentcorrection/21487180-10531527, http://linkedlifedata.com/resource/pubmed/commentcorrection/21487180-12832812, http://linkedlifedata.com/resource/pubmed/commentcorrection/21487180-17057338, http://linkedlifedata.com/resource/pubmed/commentcorrection/21487180-17587661, http://linkedlifedata.com/resource/pubmed/commentcorrection/21487180-18566507, http://linkedlifedata.com/resource/pubmed/commentcorrection/21487180-19171973, http://linkedlifedata.com/resource/pubmed/commentcorrection/21487180-1925561, http://linkedlifedata.com/resource/pubmed/commentcorrection/21487180-19844017, http://linkedlifedata.com/resource/pubmed/commentcorrection/21487180-19844027, http://linkedlifedata.com/resource/pubmed/commentcorrection/21487180-9757086
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
May
pubmed:issn
1600-5724
pubmed:author
pubmed:issnType
Electronic
pubmed:volume
67
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
219-28
pubmed:dateRevised
2011-7-28
pubmed:meshHeading
pubmed:year
2011
pubmed:articleTitle
Translation calibration of inverse-kappa goniometers in macromolecular crystallography.
pubmed:affiliation
European Molecular Biology Laboratory, Grenoble, France. brockhauser@embl.fr