pubmed:abstractText
The combination of Pleth Variability Index (PVI) and passive leg raising (PLR)-induced pulse pressure variation may help to diagnose hypovolemia in spontaneously breathing patients. In 44 subjects, PVI and Pulse Pressure (PP) variation after PLR were measured before and after induced hypovolemia (blood gift or hemodialysis session). PVI values were significantly greater after hemodialysis session or blood gift (22% vs 18%, P = 0.03); in contrast PP variation did not change significantly (7% vs 4%, P = 0.49). The accuracy of these parameters or of their combination to identify the "after hypovolemia induction" period was weak. In spontaneous ventilation, PVI value is greater after induced hypovolemia, whereas PP variation does not change significantly. The combination of PVI and PLR does not improve the accuracy of the detection of induced hypovolemia.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:issn
0001-5164
pubmed:author
pubmed:issnType
Print
pubmed:volume
61
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
147-50
pubmed:meshHeading
pubmed:year
2010
pubmed:articleTitle
Pleth variability index combined with passive leg raising-induced pulse pressure variation to detect hypovolemia in spontaneously breathing patients.
pubmed:affiliation
Departments of Anesthesiology, Cliniques universitaires Saint-Luc, Université catholique de Louvain, Brussels, Belgium.
pubmed:publicationType
Journal Article