pubmed:abstractText
Biaxial testing has been used widely to characterize the mechanical properties of soft tissues and other flexible materials, but fundamental issues related to specimen design and attachment have remained. Finite element models and experiments were used to investigate how specimen geometry and attachment details affect uniformity of the strain field inside the attachment points. The computational studies confirm that increasing the number of attachment points increases the size of the area that experiences sensibly uniform strain (defined here as the central sample region where the ratio of principal strains E(11)/E(22)<1.10), and that the strains experienced in this region are less than nominal strains based on attachment point movement. Uniformity of the strain field improves substantially when the attachment points span a wide zone along each edge. Subtle irregularities in attachment point positioning can significantly degrade strain field uniformity. In contrast, details of the apron, the region outside of the attachment points, have little effect on the interior strain field. When nonlinear properties consistent with those found in human sclera are used, similar results are found. Experiments were conducted on 6 x 6 mm talc-sprinkled rubber specimens loaded using wire "rakes." Points on a grid having 12 x 12 bays were tracked, and a detailed strain map was constructed. A finite element model based on the actual geometry of an experiment having an off-pattern rake tine gave strain patterns that matched to within 4.4%. Finally, simulations using nonequibiaxial strains indicated that the strain field uniformity was more sensitive to sample attachment details for the nonequibiaxial case as compared to the equibiaxial case. Specimen design and attachment were found to significantly affect the uniformity of the strain field produced in biaxial tests. Practical guidelines were offered for design and mounting of biaxial test specimens. The issues addressed here are particularly relevant as specimens become smaller in size.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:month
Sep
pubmed:issn
1528-8951
pubmed:author
pubmed:issnType
Electronic
pubmed:volume
131
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
091003
pubmed:meshHeading
pubmed:year
2009
pubmed:articleTitle
Strain uniformity in biaxial specimens is highly sensitive to attachment details.
pubmed:affiliation
Department of Mechanical and Industrial Engineering, and Institute for Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada.
pubmed:publicationType
Journal Article, Research Support, Non-U.S. Gov't