Source:http://linkedlifedata.com/resource/pubmed/id/18975703
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
10
|
pubmed:dateCreated |
2008-11-3
|
pubmed:abstractText |
The aim of this study was to assess the potential of a modern x,y,z modulation-based automatic exposure control system (AEC) for dose reduction in pediatric and adult multidetector CT (MDCT) imaging and evaluate the quality of the images obtained. Five physical anthropomorphic phantoms that simulate the average individual as neonate, 1-, 5-, 10-year old child, and adult were scanned with a MDCT scanner, equipped with a modern AEC system. Dose reduction (%DR) was calculated as the percentage difference of the mean modulated and the preset tube current-time product that is prescribed for standard head and body scan protocols. The effect of the tube potential and the orientation of the topogram acquisition on dose reduction were assessed. Image quality was evaluated on the basis of image noise and signal to noise ratio (SNR). The dose reduction values achieved in pediatric phantoms were remarkably lower than those achieved for the adult. The efficiency of the AEC is decreased at 80 kVp compared to higher tube potentials and for helical scans following an anterior posterior (AP-AEC) compared to a lateral (LAT-AEC) topogram acquisition. In AP-AEC scans, the dose reduction ranged between 4.7 and 34.7% for neonate, 15.4 and 30.9% for 1 year old, 3.1 and 26.7% for 5 years old, 1.2 and 58.7% for 10 years old, and 15.5 and 57.4% for adult. In LAT-AEC scans, the corresponding dose reduction ranged between 11.0 and 36.5%, 27.2 and 35.7%, 11.3 and 35.6%, 0.3 and 67.0%, and 15.0 and 61.7%, respectively. AP-AEC scans resulted in a 17.1% and 19.7% dose increase in the thorax of neonate and the pelvis of the 10-year old phantom, respectively. The variation in the measured noise among images obtained along the scanning z axis was lower in AEC activated compared to fixed milliamperes scans. However, image noise was significantly increased (P<.001) and SNR significantly decreased (P<.001) in most AEC activated compared to fixed milliamperes scans. In conclusion, AEC resulted in a (i) substantial dose reduction, which is less pronounced in children compared to adult, (ii) higher dose reduction in scans following a lateral compared to scans following an anterior-posterior topogram acquisition, (iii) increase of image noise and degradation of SNR in the obtained images compared to the fixed milliamperes technique.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Oct
|
pubmed:issn |
0094-2405
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
35
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
4567-76
|
pubmed:meshHeading |
pubmed-meshheading:18975703-Adult,
pubmed-meshheading:18975703-Algorithms,
pubmed-meshheading:18975703-Body Burden,
pubmed-meshheading:18975703-Child,
pubmed-meshheading:18975703-Humans,
pubmed-meshheading:18975703-Phantoms, Imaging,
pubmed-meshheading:18975703-Radiographic Image Enhancement,
pubmed-meshheading:18975703-Radiographic Image Interpretation, Computer-Assisted,
pubmed-meshheading:18975703-Radiometry,
pubmed-meshheading:18975703-Reproducibility of Results,
pubmed-meshheading:18975703-Robotics,
pubmed-meshheading:18975703-Sensitivity and Specificity,
pubmed-meshheading:18975703-Tomography, X-Ray Computed
|
pubmed:year |
2008
|
pubmed:articleTitle |
Automatic exposure control in pediatric and adult multidetector CT examinations: a phantom study on dose reduction and image quality.
|
pubmed:affiliation |
Department of Medical Physics, Faculty of Medicine, University of Crete, P.O. Box 1352, Iraklion 71110, Crete, Greece. apapadak@edu.med.uoc.gr
|
pubmed:publicationType |
Journal Article
|