Source:http://linkedlifedata.com/resource/pubmed/id/18814193
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
2
|
pubmed:dateCreated |
2009-1-15
|
pubmed:abstractText |
A highly sensitive and specific LC-MS/MS method has been developed and validated for the estimation of pramipexole (PPX) with 500 microL human plasma using memantine as an internal standard (IS). The API-4000 was operated under multiple-reaction monitoring mode (MRM) using the electrospray ionization technique. Solid-phase extraction was used to extract PPX and IS from human plasma. The resolution of peaks was achieved with 0.01 m ammonium acetate buffer (pH 4.4):acetonitrile (30:70, v/v) on a Discovery CN column. The total chromatographic run time was 3.0 min and the elution of PPX and IS occurred at approximately 2.32 and 2.52, respectively. The MS/MS ion transitions monitored were 212.10 --> 153.10 for PPX and 180.20 --> 107.30 for IS. The method was proved to be accurate and precise at linearity range of 20-3540 pg/mL with a correlation coefficient (r) of > or =0.999. The intra- and inter-day precision and accuracy values found to be within the assay variability limits as per the FDA guidelines. The developed assay method was applied to a pharmacokinetic study in human volunteers following oral administration of 0.25 mg PPX tablet.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Feb
|
pubmed:issn |
1099-0801
|
pubmed:author | |
pubmed:copyrightInfo |
Copyright (c) 2008 John Wiley & Sons, Ltd.
|
pubmed:issnType |
Electronic
|
pubmed:volume |
23
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
212-8
|
pubmed:dateRevised |
2009-7-17
|
pubmed:meshHeading |
pubmed-meshheading:18814193-Benzothiazoles,
pubmed-meshheading:18814193-Chromatography, Liquid,
pubmed-meshheading:18814193-Dopamine Agonists,
pubmed-meshheading:18814193-Drug Stability,
pubmed-meshheading:18814193-Humans,
pubmed-meshheading:18814193-Linear Models,
pubmed-meshheading:18814193-Memantine,
pubmed-meshheading:18814193-Reference Standards,
pubmed-meshheading:18814193-Reproducibility of Results,
pubmed-meshheading:18814193-Sensitivity and Specificity,
pubmed-meshheading:18814193-Solid Phase Extraction,
pubmed-meshheading:18814193-Spectrometry, Mass, Electrospray Ionization,
pubmed-meshheading:18814193-Tandem Mass Spectrometry
|
pubmed:year |
2009
|
pubmed:articleTitle |
Development and validation of a sensitive LC-MS/MS method with electrospray ionization for quantitation of pramipexole in human plasma: application to a clinical pharmacokinetic study.
|
pubmed:affiliation |
Bioanalytical Department, Integrated Product Development, Dr Reddy's Laboratories Ltd, Bachupalli, Hyderabad-500 072, India.
|
pubmed:publicationType |
Journal Article,
Validation Studies
|