Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
19
pubmed:dateCreated
2008-8-13
pubmed:abstractText
Binocular disparities applied to large-field patterns elicit vergence eye movements at ultra-short latencies. We used the electromagnetic search coil technique to record the horizontal and vertical positions of both eyes while subjects briefly viewed (150 ms) large patterns that were identical at the two eyes except for a difference in position (binocular disparity) that was varied in direction from trial to trial. For accurate alignment with the stimuli, the horizontal and vertical disparity vergence responses (HDVRs, VDVRs) should vary as the sine and cosine, respectively, of the direction of the disparity stimulus vector. In a first experiment, using random-dots patterns (RDs) with a binocular disparity of 0.2 degrees , this was indeed the case. In a second experiment, using 1-D sine-wave gratings with a binocular phase difference (disparity) of 1/4-wavelength, it was not the case: HDVRs were maximal when the grating was vertical and showed little decrement until the grating was oriented more than approximately 65 degrees away from vertical, whereas VDVRs were maximal when the grating was horizontal and began to decrement roughly linearly when the grating was oriented away from the horizontal. We attribute these complex directional dependencies with gratings to the aperture problem, and the HDVR data strongly resemble the stereothresholds for 1-D gratings, which are minimal when the gratings are vertical and remain constant for orientations up to approximately 80 degrees away from the vertical when expressed as spatial phase disparities [Morgan, M. J., & Castet, E. (1997). The aperture problem in stereopsis. Vision Research, 37, 2737-2744.]. To explain this constancy of stereothresholds, Morgan and Castet (1997) postulated detectors sensitive to the phase disparity of the gratings seen by the two eyes (rather than their linear separation along some fixed axis, such as the horizontal). However, because (1) our VDVR data with gratings did not show this constancy and (2) the available evidence strongly suggests that there are no major differences in the disparity detectors mediating the initial HDVR and VDVR, we sought an alternative explanation for our data. We show that the dependence of the initial HDVR and VDVR on grating orientation can be successfully modeled by a bias in the number and/or efficacy of the detectors that favors horizontal disparities.
pubmed:grant
pubmed:commentsCorrections
http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-10444686, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-10844045, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-11247983, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-11353039, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-1136166, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-11960812, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-12020078, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-12106142, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-12106143, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-12167860, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-12424321, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-12466456, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-12536000, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-12676244, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-12688669, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-12867533, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-13129536, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-14121113, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-14765951, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-1504027, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-15333204, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-16129469, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-16306321, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-16765403, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-16908495, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-17118422, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-17209738, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-17234585, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-17706738, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-18184571, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-2396096, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-3445485, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-3454431, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-3559991, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-3722457, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-3722458, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-6666067, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-6740978, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-7617417, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-8191289, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-8249313, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-8586555, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-8727386, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-8759452, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-8762765, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-8776445, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-9176952, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-9176953, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-9176954, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-9305841, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-9305842, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-9334433, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-9373672, http://linkedlifedata.com/resource/pubmed/commentcorrection/18675438-9415368
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:month
Sep
pubmed:issn
0042-6989
pubmed:author
pubmed:issnType
Print
pubmed:volume
48
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
2006-19
pubmed:dateRevised
2010-9-22
pubmed:meshHeading
pubmed:year
2008
pubmed:articleTitle
Human vergence eye movements to oblique disparity stimuli: evidence for an anisotropy favoring horizontal disparities.
pubmed:affiliation
Laboratory of Sensorimotor Research, National Eye Institute, National Institutes of Health, 49 Convent Drive, Bethesda, MD 20892, USA. ramboldh@nei.nih.gov
pubmed:publicationType
Journal Article, Research Support, Non-U.S. Gov't, Research Support, N.I.H., Intramural