pubmed:abstractText |
An analytical method was developed for the determination of enantiomers of dencichine in plasma. Sample extraction from plasma was achieved by a solid-phase extraction (SPE) procedure using a C(18) cartridge, with carbocisteine as the internal standard. Plasma was deproteinized using inorganic acid and derivatizated before the SPE. Chiral separation of dencichine enantiomers was achieved by pre-column derivatization using o-phthaldialdehyde (OPA) and the chiral thiol N-isobutanoyl-L-cysteine (NIBC) to form diastereoisomeric isoindole derivatives that were separable by ODS column using a gradient solvent programme. The column eluent was monitored using mass spectrometry (MS). The conditions of MS detection were optimized, and selected ion monitoring was used to selectively detect D-dencichine and its arrangement isomer. High sensitivity and selectivity were obtained using this method. The limit of detection was determined to be 10 ng/ml for D-dencichine and 8 ng/ml for L-dencichine in plasma. The linearity was demonstrated over a wide range of concentrations, from 0.5 to 50 microg/ml for both enatiomers. The intra- and inter-day precision (C.V.), studied at four concentrations, was less than 7.0%. No interferences from endogenous amino acids and isomers of dencichine were found. The method was suitable for pharmacokinetic studies of dencichine enantiomers.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Aug
|
pubmed:issn |
1570-0232
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:day |
18
|
pubmed:volume |
840
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
124-31
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading |
pubmed-meshheading:16730243-Amino Acids, Diamino,
pubmed-meshheading:16730243-Animals,
pubmed-meshheading:16730243-Chromatography, Gas,
pubmed-meshheading:16730243-Chromatography, High Pressure Liquid,
pubmed-meshheading:16730243-Rabbits,
pubmed-meshheading:16730243-Reference Standards,
pubmed-meshheading:16730243-Reproducibility of Results,
pubmed-meshheading:16730243-Sensitivity and Specificity,
pubmed-meshheading:16730243-Spectrometry, Mass, Electrospray Ionization,
pubmed-meshheading:16730243-Stereoisomerism
|
pubmed:year |
2006
|
pubmed:articleTitle |
Enantioselective determination of dencichine in rabbit plasma by high-performance liquid chromatography-electrospray mass spectrometry.
|
pubmed:affiliation |
School of Pharmacy, Sichuan University, Chengdu 610041, China.
|
pubmed:publicationType |
Journal Article,
Research Support, Non-U.S. Gov't
|