pubmed:abstractText
Ascending aortic dissection is a known complication of cardiac surgery. Off-pump coronary artery bypass surgery seems to be associated with a higher risk for this event as compared with on-pump bypass surgery. This increased risk may result from aortic side-clamping under pulsatile flow as opposed to continuous flow in conventional bypass surgery. Mechanical devices allowing performance of proximal bypass anastomoses without aortic side-clamping are supposed to reduce the risk for aortic dissection. We report a case in which ascending aortic dissection occurred 8 days after off-pump bypass surgery, most likely arising from a mechanically performed proximal bypass anastomosis.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
AIM
pubmed:status
MEDLINE
pubmed:month
Jul
pubmed:issn
1552-6259
pubmed:author
pubmed:issnType
Electronic
pubmed:volume
80
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
316-8
pubmed:meshHeading
pubmed:year
2005
pubmed:articleTitle
Aortic dissection with potential origin from a mechanical bypass anastomosis.
pubmed:affiliation
Department of Cardiovascular Surgery, City Hospital Triemli, Zurich, Switzerland.
pubmed:publicationType
Journal Article, Case Reports