pubmed:abstractText |
A fast photoacoustic (PA) imaging system, based on a 320-transducer linear array, was developed and tested on a tissue phantom. To reconstruct a test tomographic image, 64 time-domain PA signals were acquired from a tissue phantom with embedded light-absorption targets. A signal acquisition was accomplished by utilizing 11 phase-controlled sub-arrays, each consisting of four transducers. The results show that the system can rapidly map the optical absorption of a tissue phantom and effectively detect the embedded light-absorbing target. By utilizing the multi-element linear transducer array and phase-controlled imaging algorithm, we thus can acquire PA tomography more efficiently, compared to other existing technology and algorithms. The methodology and equipment thus provide a rapid and reliable approach to PA imaging that may have potential applications in noninvasive imaging and clinic diagnosis.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Apr
|
pubmed:issn |
0031-9155
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:day |
7
|
pubmed:volume |
49
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
1339-46
|
pubmed:dateRevised |
2008-11-21
|
pubmed:meshHeading |
pubmed-meshheading:15128209-Acoustics,
pubmed-meshheading:15128209-Algorithms,
pubmed-meshheading:15128209-Equipment Design,
pubmed-meshheading:15128209-Equipment Failure Analysis,
pubmed-meshheading:15128209-Image Enhancement,
pubmed-meshheading:15128209-Image Interpretation, Computer-Assisted,
pubmed-meshheading:15128209-Lasers,
pubmed-meshheading:15128209-Optics and Photonics,
pubmed-meshheading:15128209-Phantoms, Imaging,
pubmed-meshheading:15128209-Reproducibility of Results,
pubmed-meshheading:15128209-Sensitivity and Specificity,
pubmed-meshheading:15128209-Tomography,
pubmed-meshheading:15128209-Transducers,
pubmed-meshheading:15128209-Ultrasonography,
pubmed-meshheading:15128209-Vibration
|
pubmed:year |
2004
|
pubmed:articleTitle |
Fast photoacoustic imaging system based on 320-element linear transducer array.
|
pubmed:affiliation |
Institute of Laser Life Science, South China Normal University, Guangzhou 510631, People's Republic of China.
|
pubmed:publicationType |
Journal Article,
Comparative Study,
Research Support, Non-U.S. Gov't,
Evaluation Studies,