pubmed-article:15047412pubmed:abstractTextThe technique of harmonic motion imaging (HMI) uses the localized stimulus of the oscillatory ultrasonic radiation force as produced by two overlapping beams of distinct frequencies, and estimates the resulting harmonic displacement in the tissue in order to assess its underlying mechanical properties. In this paper, we studied the relationship between measured displacement and stiffness in gels and tissues in vitro. Two focused ultrasound transducers with a 100 mm focal length were used at frequencies of 3.7500 MHz and either 3.7502 (or 3.7508 MHz), respectively, in order to produce an oscillatory motion at 200 Hz in the gel or tissue. A 1.1 MHz diagnostic transducer (Imasonics, Inc.) was also focused at 100 mm and acquired 5 ms RF signals (pulse repetition frequency (PRF)=3.5 kHz) at 100 MHz sampling frequency during radiation force application. First, three 50x50 mm(2) acrylamide gels were prepared at concentrations of 4%, 8% and 16%. The resulting displacement was estimated using crosscorrelation techniques between successively acquired RF signals with a 2 mm window and 80% window overlap at 1260 W/cm(2). A normal 1-D indentation instrument (TeMPeST) applied oscillatory loads at 0.1-200 Hz with a 5 mm-diameter flat indenter. Then, 12 displacement measurements in 6 porcine muscle specimens (two measurements/case, as above) were made in vitro, before and after ablation which was performed for 10 s at 1260 W/cm(2). In all gel cases, the harmonic displacement was found to linearly increase with intensity and exponentially decrease with gel concentration. The TeMPeST measurements showed that the elastic moduli for the 4%, 8% and 16% gels equaled 3.93+/-0.06, 17.1+/-0.2 and 75+/-2 kPa, respectively, demonstrating that the HMI displacement estimate depends directly on the gel stiffness. Finally, in the tissues samples, the mean displacement amplitude showed a twofold decrease between non-ablated and ablated tissue, demonstrating a correspondence between the HMI response and an increase in stiffness measured with the TeMPeST instrument.lld:pubmed
pubmed-article:15047412pubmed:granthttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:15047412pubmed:languageenglld:pubmed
pubmed-article:15047412pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:15047412pubmed:citationSubsetIMlld:pubmed
pubmed-article:15047412pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:15047412pubmed:statusMEDLINElld:pubmed
pubmed-article:15047412pubmed:monthAprlld:pubmed
pubmed-article:15047412pubmed:issn0041-624Xlld:pubmed
pubmed-article:15047412pubmed:authorpubmed-author:HynynenKKlld:pubmed
pubmed-article:15047412pubmed:authorpubmed-author:DawsonS LSLlld:pubmed
pubmed-article:15047412pubmed:authorpubmed-author:KonofagouE...lld:pubmed
pubmed-article:15047412pubmed:authorpubmed-author:OttensmeyerMMlld:pubmed
pubmed-article:15047412pubmed:authorpubmed-author:AgabianSSlld:pubmed
pubmed-article:15047412pubmed:issnTypePrintlld:pubmed
pubmed-article:15047412pubmed:volume42lld:pubmed
pubmed-article:15047412pubmed:ownerNLMlld:pubmed
pubmed-article:15047412pubmed:authorsCompleteYlld:pubmed
pubmed-article:15047412pubmed:pagination951-6lld:pubmed
pubmed-article:15047412pubmed:dateRevised2009-11-11lld:pubmed
pubmed-article:15047412pubmed:meshHeadingpubmed-meshheading:15047412...lld:pubmed
pubmed-article:15047412pubmed:meshHeadingpubmed-meshheading:15047412...lld:pubmed
pubmed-article:15047412pubmed:meshHeadingpubmed-meshheading:15047412...lld:pubmed
pubmed-article:15047412pubmed:meshHeadingpubmed-meshheading:15047412...lld:pubmed
pubmed-article:15047412pubmed:meshHeadingpubmed-meshheading:15047412...lld:pubmed
pubmed-article:15047412pubmed:meshHeadingpubmed-meshheading:15047412...lld:pubmed
pubmed-article:15047412pubmed:meshHeadingpubmed-meshheading:15047412...lld:pubmed
pubmed-article:15047412pubmed:meshHeadingpubmed-meshheading:15047412...lld:pubmed
pubmed-article:15047412pubmed:meshHeadingpubmed-meshheading:15047412...lld:pubmed
pubmed-article:15047412pubmed:meshHeadingpubmed-meshheading:15047412...lld:pubmed
pubmed-article:15047412pubmed:year2004lld:pubmed
pubmed-article:15047412pubmed:articleTitleEstimating localized oscillatory tissue motion for assessment of the underlying mechanical modulus.lld:pubmed
pubmed-article:15047412pubmed:affiliationDepartment of Biomedical Engineering, Columbia University, New York, NY 10027, USA. ek2191@columbia.edulld:pubmed
pubmed-article:15047412pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:15047412pubmed:publicationTypeIn Vitrolld:pubmed
pubmed-article:15047412pubmed:publicationTypeResearch Support, U.S. Gov't, P.H.S.lld:pubmed
pubmed-article:15047412pubmed:publicationTypeResearch Support, Non-U.S. Gov'tlld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:15047412lld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:15047412lld:pubmed