Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
4
|
pubmed:dateCreated |
1993-4-16
|
pubmed:abstractText |
Recently, theoretical investigations of the beamforming capability of two-dimensional (2-D) transducer arrays have characterized the array parameters required to steer a symmetrically focused ultrasound beam up to 45 degrees off-axis. These investigations have also shown that the number of elements in a steered 2-D array can be dramatically reduced by using a sparse set of elements, randomly distributed throughout the aperture of the transducer. The penalty paid for the use of a sparse array is the development of a "pedestal" sidelobe in the beam profile, the amplitude of which increases as the number of elements in the array decreases. In this paper the potential of 2-D arrays for medical imaging is assessed by simulating B-scan images of spherical lesions, both cystic and scattering, embedded in a large random scattering volume. Similar contrast characteristics over a range of cyst sizes are demonstrated for a dense 2-D array and a sparse array with 1/8th the number of elements, both operating at 5 MHz. A 32nd order sparse array is shown to perform at a reduced level, producing unacceptable artifactual echoes within images of cysts. The 8th order sparse array pattern has been fabricated on a fixed-focus poly(vinylidene difluoride) transducer using photolithographic techniques. Experimental images from this transducer are used to verify some of the theoretical predictions made in this paper. Comparisons between simulated B-scan images from linear and 2-D phased arrays are presented in a companion paper.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Oct
|
pubmed:issn |
0161-7346
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
14
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
323-43
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading |
pubmed-meshheading:1296337-Artifacts,
pubmed-meshheading:1296337-Cysts,
pubmed-meshheading:1296337-Humans,
pubmed-meshheading:1296337-Image Enhancement,
pubmed-meshheading:1296337-Models, Structural,
pubmed-meshheading:1296337-Technology, Radiologic,
pubmed-meshheading:1296337-Transducers,
pubmed-meshheading:1296337-Ultrasonography
|
pubmed:year |
1992
|
pubmed:articleTitle |
Simulation of B-scan images from two-dimensional transducer arrays: Part I--Methods and quantitative contrast measurements.
|
pubmed:affiliation |
Department of Medical Biophysics, University of Toronto, Ontario, Canada.
|
pubmed:publicationType |
Journal Article,
Research Support, Non-U.S. Gov't
|