Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
6
pubmed:dateCreated
2001-2-2
pubmed:abstractText
1. The effect of the novel ET(A) receptor antagonist LBL 031 and other selective and mixed endothelin receptor antagonists on endothelin-1 (ET-1)-induced and lipopolysaccharide (LPS)-induced microvascular leakage was assessed in rat airways. 2. Intravenously administered ET-1 (1 nmole kg(-1)) or LPS (30 mg kg(-1)) caused a significant increase in microvascular leakage in rat airways when compared to vehicle treated animals. 3. Pre-treatment with the selective ET(A) receptor antagonists, LBL 031 or PD 156707, or the mixed ET(A/B) receptor antagonist, bosentan (each at 30 mg kg(-1)), reduced ET-1-induced leakage to baseline levels. ET-1-induced leakage was not reduced by pre-treatment with the ET(B) selective antagonist BQ 788 (3 mg kg(-1)). 4. Pre-treatment with the selective ET(A) receptor antagonist, LBL 031 (0.1 mg kg(-1)) or PD 156707 (10 mg kg(-1)), or the mixed ET(A/B) receptor antagonist, bosentan (30 mg kg(-1)), reduced LPS-induced leakage by 54, 48 and 59% respectively. LPS-induced leakage was not affected by pre-treatment with the ET(B) selective antagonist BQ 788 (3 mg kg(-1)). 5. The data suggests that ET-1-induced microvascular leakage in the rat airway is ET(A) receptor mediated and that part of the increase induced by LPS may be due to the actions of ET-1. Therefore, a potent ET(A) receptor selective antagonist, such as LBL 031, may provide a suitable treatment for inflammatory diseases of the airways, especially those involving LPS and having an exudative phase, such as the septic shock-induced adult respiratory distress syndrome.
pubmed:commentsCorrections
http://linkedlifedata.com/resource/pubmed/commentcorrection/11082120-10715156, http://linkedlifedata.com/resource/pubmed/commentcorrection/11082120-2451132, http://linkedlifedata.com/resource/pubmed/commentcorrection/11082120-3202424, http://linkedlifedata.com/resource/pubmed/commentcorrection/11082120-4037521, http://linkedlifedata.com/resource/pubmed/commentcorrection/11082120-7582310, http://linkedlifedata.com/resource/pubmed/commentcorrection/11082120-7615852, http://linkedlifedata.com/resource/pubmed/commentcorrection/11082120-7791115, http://linkedlifedata.com/resource/pubmed/commentcorrection/11082120-7858876, http://linkedlifedata.com/resource/pubmed/commentcorrection/11082120-7917311, http://linkedlifedata.com/resource/pubmed/commentcorrection/11082120-8035319, http://linkedlifedata.com/resource/pubmed/commentcorrection/11082120-8256914, http://linkedlifedata.com/resource/pubmed/commentcorrection/11082120-8310408, http://linkedlifedata.com/resource/pubmed/commentcorrection/11082120-8355554, http://linkedlifedata.com/resource/pubmed/commentcorrection/11082120-8472750, http://linkedlifedata.com/resource/pubmed/commentcorrection/11082120-8733595, http://linkedlifedata.com/resource/pubmed/commentcorrection/11082120-8904561, http://linkedlifedata.com/resource/pubmed/commentcorrection/11082120-9117019, http://linkedlifedata.com/resource/pubmed/commentcorrection/11082120-9279246, http://linkedlifedata.com/resource/pubmed/commentcorrection/11082120-9569231, http://linkedlifedata.com/resource/pubmed/commentcorrection/11082120-9607370
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Nov
pubmed:issn
0007-1188
pubmed:author
pubmed:issnType
Print
pubmed:volume
131
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
1129-34
pubmed:dateRevised
2009-11-18
pubmed:meshHeading
pubmed:year
2000
pubmed:articleTitle
Effect of endothelin antagonists, including the novel ET(A) receptor antagonist LBL 031, on endothelin-1 and lipopolysaccharide-induced microvascular leakage in rat airways.
pubmed:affiliation
Department of Pharmacology, Research & Development, Aventis Pharma, Rainham Road South, Dagenham, Essex RM10 7XS.
pubmed:publicationType
Journal Article