pubmed:abstractText
The QUANTIPLEX HIV-1 RNA assay, version 3.0 (a branched DNA, version 3.0, assay [bDNA 3.0 assay]), was evaluated by analyzing spiked and clinical plasma samples and was compared with the AMPLICOR HIV-1 MONITOR Ultrasensitive (ultrasensitive reverse transcription-PCR [US-RT-PCR]) method. A panel of spiked plasma samples that contained 0 to 750,000 copies of human immunodeficiency virus type 1 (HIV-1) RNA per ml was tested four times in each of four laboratories (1,344 assays). Negative results (<50 copies/ml) were obtained in 30 of 32 (94%) assays with seronegative samples, 66 of 128 (52%) assays with HIV-1 RNA at 50 copies/ml, and 5 of 128 (4%) assays with HIV-1 RNA at 100 copies/ml. The assay was linear from 100 to 500,000 copies/ml. The within-run standard deviation (SD) of the log(10) estimated HIV-1 RNA concentration was 0.08 at 1,000 to 500,000 copies/ml, increased below 1,000 copies/ml, and was 0.17 at 100 copies/ml. Between-run reproducibility at 100 to 500 copies/ml was <0.10 log(10) in most comparisons. Interlaboratory differences across runs were </=0.10 log(10) at all concentrations examined. A subset of the panel (25 to 500 copies/ml) was also analyzed by the US-RT-PCR assay. The within-run SD varied inversely with the log(10) HIV-1 RNA concentration but was higher than the SD for the bDNA 3.0 assay at all concentrations. Log-log regression analysis indicated that the two methods produced very similar estimates at 100 to 500 copies/ml. In parallel testing of clinical specimens with low HIV-1 RNA levels, 80 plasma samples with <50 copies/ml by the US-RT-PCR assay had <50 copies/ml when they were retested by the bDNA 3.0 assay. In contrast, 11 of 78 (14%) plasma samples with <50 copies/ml by the bDNA 3.0 assay had >/=50 copies/ml when they were retested by the US-RT-PCR assay (median, 86 copies/ml; range, 50 to 217 copies/ml). Estimation of bDNA 3.0 values of <50 copies/ml by extending the standard curve of the assay showed that these samples with discrepant results had higher HIV-1 RNA levels than the samples with concordant results (median, 34 versus 17 copies/ml; P = 0.0051 by the Wilcoxon two-sample test). The excellent reproducibility, broad linear range, and good sensitivity of the bDNA 3.0 assay make it a very attractive method for quantitation of HIV-1 RNA levels in plasma.
pubmed:grant
pubmed:commentsCorrections
http://linkedlifedata.com/resource/pubmed/commentcorrection/10921936-10093977, http://linkedlifedata.com/resource/pubmed/commentcorrection/10921936-10341272, http://linkedlifedata.com/resource/pubmed/commentcorrection/10921936-10341273, http://linkedlifedata.com/resource/pubmed/commentcorrection/10921936-10356140, http://linkedlifedata.com/resource/pubmed/commentcorrection/10921936-10523562, http://linkedlifedata.com/resource/pubmed/commentcorrection/10921936-10553788, http://linkedlifedata.com/resource/pubmed/commentcorrection/10921936-10585790, http://linkedlifedata.com/resource/pubmed/commentcorrection/10921936-10647802, http://linkedlifedata.com/resource/pubmed/commentcorrection/10921936-7697440, http://linkedlifedata.com/resource/pubmed/commentcorrection/10921936-8366168, http://linkedlifedata.com/resource/pubmed/commentcorrection/10921936-8599114, http://linkedlifedata.com/resource/pubmed/commentcorrection/10921936-8638160, http://linkedlifedata.com/resource/pubmed/commentcorrection/10921936-8897167, http://linkedlifedata.com/resource/pubmed/commentcorrection/10921936-9114426, http://linkedlifedata.com/resource/pubmed/commentcorrection/10921936-9134873, http://linkedlifedata.com/resource/pubmed/commentcorrection/10921936-9182471, http://linkedlifedata.com/resource/pubmed/commentcorrection/10921936-9224596, http://linkedlifedata.com/resource/pubmed/commentcorrection/10921936-9308639, http://linkedlifedata.com/resource/pubmed/commentcorrection/10921936-9504519, http://linkedlifedata.com/resource/pubmed/commentcorrection/10921936-9738051, http://linkedlifedata.com/resource/pubmed/commentcorrection/10921936-9764780, http://linkedlifedata.com/resource/pubmed/commentcorrection/10921936-9890848, http://linkedlifedata.com/resource/pubmed/commentcorrection/10921936-9986856
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Aug
pubmed:issn
0095-1137
pubmed:author
pubmed:issnType
Print
pubmed:volume
38
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
2837-45
pubmed:dateRevised
2009-11-18
pubmed:meshHeading
pubmed:year
2000
pubmed:articleTitle
Performance characteristics of the QUANTIPLEX HIV-1 RNA 3.0 assay for detection and quantitation of human immunodeficiency virus type 1 RNA in plasma.