Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
5
pubmed:dateCreated
1998-12-24
pubmed:abstractText
We compared retrospectively the radiographic migration profiles of 82 acetabular components in 61 patients having rheumatoid arthritis with those of 45 hips having arthrosis who underwent a standardized technique of cementless arthroplasty with the Zweymüller prosthesis (Alloclassic). We used a modification of Dickob's technique of digital migration analysis that corrects for magnification errors and horizontal pelvic tilt. The rheumatoid patients were stratified as having oligoarticular, polyarticular, or mutilating arthritis. The overall rate of acetabular loosening in rheumatoid hips after mean 88 (26-117) months was 4%. Loosening was seen only in cases with mutilating arthritis and acetabular protrusion, where the direction of cup migration was also clearly different from that detected in the other types of rheumatoid arthritis and in arthrosis. The different patterns of cup migration in cementless hip replacement for rheumatoid arthritis, depending on disease severity, is of importance when comparing outcome of total hip arthroplasty in rheumatoid patients.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Oct
pubmed:issn
0001-6470
pubmed:author
pubmed:issnType
Print
pubmed:volume
69
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
455-62
pubmed:dateRevised
2006-11-15
pubmed:meshHeading
pubmed-meshheading:9855224-Adult, pubmed-meshheading:9855224-Aged, pubmed-meshheading:9855224-Arthritis, Rheumatoid, pubmed-meshheading:9855224-Bias (Epidemiology), pubmed-meshheading:9855224-Bone Cements, pubmed-meshheading:9855224-Equipment Failure Analysis, pubmed-meshheading:9855224-Female, pubmed-meshheading:9855224-Hip Prosthesis, pubmed-meshheading:9855224-Humans, pubmed-meshheading:9855224-Male, pubmed-meshheading:9855224-Middle Aged, pubmed-meshheading:9855224-Osteoarthritis, Hip, pubmed-meshheading:9855224-Prosthesis Design, pubmed-meshheading:9855224-Prosthesis Failure, pubmed-meshheading:9855224-Retrospective Studies, pubmed-meshheading:9855224-Severity of Illness Index, pubmed-meshheading:9855224-Time Factors, pubmed-meshheading:9855224-Titanium, pubmed-meshheading:9855224-Treatment Outcome
pubmed:year
1998
pubmed:articleTitle
Different cup migration in rheumatoid arthritis and arthrosis: a radiographic analysis of 127 uncemented acetabular cups.
pubmed:affiliation
Department of Orthopaedics, Allgemeines Krankenhaus der Stadt Wien, Universitätsklinik für Orthopädie, Austria. Martin.Dominkus@akh-wien.ac.at
pubmed:publicationType
Journal Article, Comparative Study