Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
5
|
pubmed:dateCreated |
1999-4-7
|
pubmed:abstractText |
The capability to reliably predict long-term in vivo wear of polyethylene would be of great value for the early identification of problematic total hip designs. Formal quantitative estimates of long-term polyethylene wear were made from a series of 197 patients who had a total hip arthroplasty and who were followed for a minimum of 10 years; the estimates were based on the wear that was apparent radiographically at nominally 2 years after the operation. A newly developed digital image-analysis edge-detection procedure was applied to 1,237 archived follow-up radiographs. The edge-detection measurements were analyzed with a robust regression random-coefficients statistical formulation developed especially to address the distributions of wear rate observed across this population over time. Formal regression equations were reported, which can be used to estimate late-wear depth for a patient radiographed at a 2-year follow-up visit. Series wide, the correlation between predicted and observed wear depths was 0.73 at 4 years, with a correlation decline of approximately 0.03 per additional year.
|
pubmed:grant | |
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Sep
|
pubmed:issn |
0736-0266
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
16
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
557-63
|
pubmed:dateRevised |
2007-11-14
|
pubmed:meshHeading |
pubmed-meshheading:9820278-Aged,
pubmed-meshheading:9820278-Arthroplasty, Replacement, Hip,
pubmed-meshheading:9820278-Cohort Studies,
pubmed-meshheading:9820278-Female,
pubmed-meshheading:9820278-Hip Joint,
pubmed-meshheading:9820278-Humans,
pubmed-meshheading:9820278-Image Processing, Computer-Assisted,
pubmed-meshheading:9820278-Linear Models,
pubmed-meshheading:9820278-Male,
pubmed-meshheading:9820278-Materials Testing,
pubmed-meshheading:9820278-Polyethylenes,
pubmed-meshheading:9820278-Predictive Value of Tests
|
pubmed:year |
1998
|
pubmed:articleTitle |
Prediction of long-term polyethylene wear in total hip arthroplasty, based on early wear measurements made using digital image analysis.
|
pubmed:affiliation |
Department of Orthopaedic Surgery, University of Iowa, Iowa City 52242, USA.
|
pubmed:publicationType |
Journal Article,
Research Support, U.S. Gov't, P.H.S.,
Research Support, Non-U.S. Gov't
|