Dual chamber rate responsive pacing incorporating a mode switching option is increasingly used in patients with chronic paroxysmal atrial fibrillation and high degree AV block. Single-lead VDDR pacemakers have rarely used for this indication. The purpose of this study was to determine their reliability of atrial sensing during atrial fibrillation, the percentage of atrial synchronous ventricular pacing, and the behavior of the sinus rate outside the phases of atrial fibrillation. We studied ten patients with a single-lead VDDR pacemaker implanted for this indication. Follow-up visits were performed at predischarge and after 1, 3, 6, 12, 18, and 24 months. During the mean follow-up period of 18.9 +/- 6.9 months, the atrial sensing thresholds in sinus rhythm remained stable. Atrial synchronous ventricular stimulation was achieved in 68.7 +/- 31.2% (median 82.5%) of the whole follow-up time. All patients showed an adequate atrial rate response during sinus rhythm. Atrial fibrillation was detected by the pacemakers in 24.0 +/- 29.8% of time. In 3 of 10 patients the duration of atrial fibrillation showed a steady increase from visit to visit. The sensed amplitudes of atrial fibrillation ranged from 0.1-1.0 mV. A programmed atrial sensitivity of 0.1 mV was necessary to achieve complete sensing of atrial fibrillation. None of the patients experienced tachycardias with optimized pacemaker programming. Single-lead VDDR pacing incorporating a mode-switching option is useful in patients with high degree AV block and paroxysmal atrial fibrillation, since it provides atrial synchronous ventricular pacing in more than two-thirds of follow-up time. In a subgroup of patients, a progressive increase of the time during atrial fibrillation was demonstrated. A reliable detection of paroxysmal atrial fibrillation requires the programming of the atrial sensitivity to its most sensitive value.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:month
Oct
pubmed:issn
0147-8389
pubmed:author
pubmed:issnType
Print
pubmed:volume
21
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
1927-33
pubmed:dateRevised
2004-11-17
pubmed:meshHeading
pubmed:year
1998
pubmed:articleTitle
Paroxysmal atrial fibrillation and high degree AV block: use of single-lead VDDR pacing with mode switching.
pubmed:affiliation
II. Medical Clinic, Johannes-Gutenberg-University, Mainz, Germany.
pubmed:publicationType
Journal Article