Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
3
pubmed:dateCreated
1976-12-3
pubmed:abstractText
We measured the one-half time of 133Xe washout from the whole lung and from 9 horizontal lung regions in 6 normal men during normal breathing and at 50 breaths/min. The diaphragm was located with a contour map prior to the selection of the 9 horizontal regions. Artifacts caused by the tissue solubility of 133Xe were reduced by expressing regional clearance relative to whole lung clearance. During normal breathing there was a progressive increase in the relative clearance of 133Xe from the lung apex to the base when each region was compared to the lung as a whole. At 50 breaths/min, relative clearance increased from the lung apex only for about 18.5 to 20 cm. At that point, the relative clearance rate of the horizontal regions began to fall and at the lung base was slower than that of the whole lung. These results are consistent with the concept that dependent lung regions have longer time constants than regions at the top of the lung.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Sep
pubmed:issn
0034-5687
pubmed:author
pubmed:issnType
Print
pubmed:volume
27
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
293-303
pubmed:dateRevised
2009-11-11
pubmed:meshHeading
pubmed:year
1976
pubmed:articleTitle
Frequency dependence of regional lung clearance of 133Xe in normal men.
pubmed:publicationType
Journal Article, Research Support, U.S. Gov't, P.H.S.