pubmed:abstractText
Cooperative clinical trial group protocols frequently require off-axis point dose calculations. The Radiological Physics Center uses the calculative technique developed by Hanson et al. [Med. Phys. 7, 145-146 (1980); 7, 147-150 (1980)] to verify these calculations. In order to correct for off-axis energy changes, this technique requires off-axis half-value layer data, HVL, as a function of off-axis ray angle for the specific beam. This paper presents a formulism based on HVL mesurements on a limited number of therapy beams, which allows the calculation of an off-axis energy-correction factor for any clinical photon beam created by a linear accelerator using conventional flattening filters.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
May
pubmed:issn
0094-2405
pubmed:author
pubmed:issnType
Print
pubmed:volume
25
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
662-7
pubmed:dateRevised
2004-11-17
pubmed:meshHeading
pubmed:year
1998
pubmed:articleTitle
A generic off-axis energy correction for linac photon beam dosimetry.
pubmed:affiliation
Department of Radiation Physics, University of Texas, M. D. Anderson Cancer Center, Houston 77030, USA.
pubmed:publicationType