Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions |
umls-concept:C0009498,
umls-concept:C0014792,
umls-concept:C0038137,
umls-concept:C0175675,
umls-concept:C0178932,
umls-concept:C0229671,
umls-concept:C0237881,
umls-concept:C0449432,
umls-concept:C0699040,
umls-concept:C0750502,
umls-concept:C1179435,
umls-concept:C1524073,
umls-concept:C1527148,
umls-concept:C1548799,
umls-concept:C1705248
|
pubmed:issue |
4
|
pubmed:dateCreated |
1976-10-2
|
pubmed:abstractText |
Human red blood cells, sensitized with complement in vivo and by a variety of methods in vitro, (e.g. blood group antibody, low ionic strength, alternate pathway), were tested with a battery of anti-complement sera (anti-C3, -C3c, -C3d, -C4, -C4c). Red blood cells could be prepared by relatively simple methods to yield cells sensitized with C3 and C4, C3 but not C4, C4 but no C3, C3d with no C3c and C4d with no C4c. These cells are suitable for standarization and quality assurance of antiglobulin sera (AGS). Anti-C3d is necessary for optimal detection of sensitization of red blood cells by complement in vivo by the direct anti-globulin test (DAT). Anti-C3d may also be optimal for the indirect antiglobulin test (IAT) especially if incubation periods greater than one hour are employed. Potent anti-C4 and anti-C3 antisera made in the authors' laboratory resulted in numerous weakly positive antiglobulin tests when testing red blood cells from refrigerated clots (especially anti-C4) but red blood cells from refrigerated anticoagulated segments gave negative results. When red blood cells were incubated in normal serum at room temperature (as in the room temperature phase of a compatibility test), some positive results were again obtained with the potent anti-C4 and anti-C3 antisera. However, one commercial antiglobulin serum containing anti-complement antibodies that were at least as potent as any other commercial antiglobulin serum gave uniformly negative results under the above conditions. Anti-C4 antibodies may be omitted from anti-globulin sera without decreasing the efficacy of such antisera to be used in compatibility testing. Thus, positive results in the compatibility test due to detection of clinically insignificant cold antibodies in the IAT by the anti-complement antibodies in AGS, may be avoided if anti-C4 is omitted or is in low concentration and if the concentration of anti-C3d is carefully standardized. A higher concentration of anti-C3d could be used for compatibility tests if red blood cells from anticoagulated segments were used instead of those from clots and if a separate tube were used for the IAT at 37 C rather than using one tube for both room temperature and 37 C incubations.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:issn |
0041-1132
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
16
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
297-306
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading |
pubmed-meshheading:951725-Antibody Specificity,
pubmed-meshheading:951725-Binding Sites,
pubmed-meshheading:951725-Complement C3,
pubmed-meshheading:951725-Complement C4,
pubmed-meshheading:951725-Complement System Proteins,
pubmed-meshheading:951725-Coombs' Test,
pubmed-meshheading:951725-Erythrocytes,
pubmed-meshheading:951725-Humans,
pubmed-meshheading:951725-Immune Sera,
pubmed-meshheading:951725-Osmolar Concentration,
pubmed-meshheading:951725-Quality Control,
pubmed-meshheading:951725-Refrigeration,
pubmed-meshheading:951725-Temperature,
pubmed-meshheading:951725-Time Factors
|
pubmed:articleTitle |
The significance of red cell bound complement components in development of standards and quality assurance for the anti-complement components of antiglobulin sera.
|
pubmed:publicationType |
Journal Article,
Comparative Study,
Research Support, U.S. Gov't, P.H.S.
|