pubmed:abstractText |
To overcome the disadvantages of conventional three-dimensional time-of-flight MR angiography (3D-TOF), such as saturation or intravoxel dephasing, black blood MR angiography (BB-MRA) using an interleaved multi-slab 3D fast spin echo sequence was developed and evaluated clinically. In major branches, the contrast-to-noise ratio of the flow was not as good as 3D-TOF in BB-MRA. However, in-plane slow flow and large aneurysm were visualized better on BB-MRA than on 3D-TOF. Furthermore, BB-MRA could provide wider coverage than 3D-TOF. BB-MRA using interleaved multi-slab 3D fast spin echo is now feasible and complementary to 3D-TOF.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:issn |
0288-2043
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
15
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
385-8
|
pubmed:dateRevised |
2004-11-17
|
pubmed:meshHeading | |
pubmed:articleTitle |
Cerebral black blood MR angiography with the interleaved multi-slab three-dimensional fast spin echo sequence.
|
pubmed:affiliation |