pubmed:abstractText |
Two developments in 125I-sealed source dosimetry have necessitated swift and accurate implementation of TG43 dosimetry in clinic: (a) the dosimetry constants of 125I endorsed by the AAPM Task Group 43 Report result in calculated dose rate that deviates by as much as 15% from currently accepted dose-rate distributions, and (b) The National Institute of Standards and Technology (NIST) has proposed modifying the 125I air-kerma strength standard by approximately 10%.
|