Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
5
pubmed:dateCreated
1998-1-15
pubmed:abstractText
Heparin has been the mainstay of anti thrombic therapy in arterial repair procedures. With increasing use of synthetic patch angioplasty (polytetrafluoroethylene [PTFE] or Dacron, Medical Products, Flagstaff, AZ) to improve long-term patency and limit aneurysmal dilation, however, the use of heparin has been associated with excessive needle hole bleeding, resulting in time delay in the operating room to achieve hemostasis, as well as clinically significant blood loss. Because of the multiple sites of action of heparin in the coagulation cascade, both intravascular (desired effect) and extravascular (untoward side effect) hemostasis are impaired. The authors therefore tested the hypothesis that selective inhibition of intravascular coagulation, without significant impairment of extravascular hemostasis, would prevent clotting intraluminally while preserving hemostasis at the suture line of the patch graft. The unique position of factor IX/IXa in the coagulation cascade renders its inhibition an ideal target in this setting. The authors prepared active site blocked factor IXa (IXai) using dansyl-Glu-Gly-Arg chloromethylketone, and tested this hypothesis in a New Zealand rabbit aortotomy model with PTFE patch closure using either heparin (25 i.u./kg; n = 16) or IXai (300 micrograms/kg; n = 21). The infrarenal aorta was identified and isolated, the anti coagulant infused, aortic cross clamp placed, and aortotomy repaired with a 2 x 6 mm PTFE patch. After cross-clamp removal, blood loss was measured and time to hemostasis was recorded. Compared with heparin, IXai resulted in significantly reduce blood loss (6.97 +/- 4.4 g vs 2.72 +/- 2.51 g, respectively, p < 0.008), and time to hemostasis (2.94 +/- 0.77 min vs 2.0 +/- 0.63 min, respectively, p < 0.003). To assess long-term patency and thrombosis, 12 rabbits (given heparin; n = 6 and IXai; n = 6) were observed for up to 2 months post-operatively. No differences were observed between rabbits treated with heparin or IXai; 100% of the grafts were patent with no differences in degree of intimal hyperplasia by histologic analysis. Together, these data suggest that use of IXai in PTFE vascular repair will safely allow realization of the benefits of long-term patency and decreased aneurysmal dilatation, while eliminating the intraoperative morbidity of needle hole bleeding.
pubmed:grant
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:issn
1058-2916
pubmed:author
pubmed:issnType
Print
pubmed:volume
43
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
M526-30
pubmed:dateRevised
2007-11-14
pubmed:meshHeading
pubmed:articleTitle
Selective anticoagulation with active site blocked factor IXa in synthetic patch vascular repair results in decreased blood loss and operative time.
pubmed:affiliation
Department of Surgery, Columbia University College of Physicians & Surgeons, New York, USA.
pubmed:publicationType
Journal Article, Research Support, U.S. Gov't, P.H.S., Research Support, Non-U.S. Gov't