Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:9184423rdf:typepubmed:Citationlld:pubmed
pubmed-article:9184423lifeskim:mentionsumls-concept:C2699414lld:lifeskim
pubmed-article:9184423lifeskim:mentionsumls-concept:C0040053lld:lifeskim
pubmed-article:9184423lifeskim:mentionsumls-concept:C0016006lld:lifeskim
pubmed-article:9184423lifeskim:mentionsumls-concept:C0019116lld:lifeskim
pubmed-article:9184423lifeskim:mentionsumls-concept:C0520510lld:lifeskim
pubmed-article:9184423lifeskim:mentionsumls-concept:C0036397lld:lifeskim
pubmed-article:9184423lifeskim:mentionsumls-concept:C0200462lld:lifeskim
pubmed-article:9184423lifeskim:mentionsumls-concept:C0038136lld:lifeskim
pubmed-article:9184423lifeskim:mentionsumls-concept:C1561577lld:lifeskim
pubmed-article:9184423lifeskim:mentionsumls-concept:C1512888lld:lifeskim
pubmed-article:9184423lifeskim:mentionsumls-concept:C1514811lld:lifeskim
pubmed-article:9184423lifeskim:mentionsumls-concept:C1706462lld:lifeskim
pubmed-article:9184423pubmed:issue5lld:pubmed
pubmed-article:9184423pubmed:dateCreated1997-8-18lld:pubmed
pubmed-article:9184423pubmed:abstractTextThe term "D-dimer assay" suggests, that these assays report the concentrations of the end-stage degradation product of crosslinked fibrin. This hardly occurs in patients. Degradation products of cross-linked fibrin rather occur with a wide range of molecular weights, and comprise various numbers of the D-dimer motif. Moreover, the numerical values obtained with different "D-dimer" assays vary widely. The variations are probably due to differences in reactivity of the various monoclonal antibodies used with the various D-dimer containing degradation products as they occur in patients; and to the various calibrators with a value assigned by the manufacturers. For the reasons indicated above a calibrator in the strict sense (e.g., pure D-dimer) is not feasible. This study shows that: it appears feasible to generate a conversion factor for each of the "D-dimer" assays studied, which will make the widely varying results obtained with these kits comparable; that the conversion factors can be based on a pool of real patient samples; and that the conversion factors are pool-independent. The next and final step in this study is to prepare and make available an international reference material for use by manufacturers and others facing a comparison problem. This is being carried out, in collaboration with the NIBSC (Dr. P. Gaffney), and the material is expected to be available in early 1997.lld:pubmed
pubmed-article:9184423pubmed:languageenglld:pubmed
pubmed-article:9184423pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:9184423pubmed:citationSubsetIMlld:pubmed
pubmed-article:9184423pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:9184423pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:9184423pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:9184423pubmed:statusMEDLINElld:pubmed
pubmed-article:9184423pubmed:monthMaylld:pubmed
pubmed-article:9184423pubmed:issn0340-6245lld:pubmed
pubmed-article:9184423pubmed:authorpubmed-author:Nieuwenhuizen...lld:pubmed
pubmed-article:9184423pubmed:issnTypePrintlld:pubmed
pubmed-article:9184423pubmed:volume77lld:pubmed
pubmed-article:9184423pubmed:ownerNLMlld:pubmed
pubmed-article:9184423pubmed:authorsCompleteYlld:pubmed
pubmed-article:9184423pubmed:pagination1031-3lld:pubmed
pubmed-article:9184423pubmed:dateRevised2006-11-15lld:pubmed
pubmed-article:9184423pubmed:meshHeadingpubmed-meshheading:9184423-...lld:pubmed
pubmed-article:9184423pubmed:meshHeadingpubmed-meshheading:9184423-...lld:pubmed
pubmed-article:9184423pubmed:meshHeadingpubmed-meshheading:9184423-...lld:pubmed
pubmed-article:9184423pubmed:meshHeadingpubmed-meshheading:9184423-...lld:pubmed
pubmed-article:9184423pubmed:meshHeadingpubmed-meshheading:9184423-...lld:pubmed
pubmed-article:9184423pubmed:meshHeadingpubmed-meshheading:9184423-...lld:pubmed
pubmed-article:9184423pubmed:meshHeadingpubmed-meshheading:9184423-...lld:pubmed
pubmed-article:9184423pubmed:meshHeadingpubmed-meshheading:9184423-...lld:pubmed
pubmed-article:9184423pubmed:meshHeadingpubmed-meshheading:9184423-...lld:pubmed
pubmed-article:9184423pubmed:meshHeadingpubmed-meshheading:9184423-...lld:pubmed
pubmed-article:9184423pubmed:year1997lld:pubmed
pubmed-article:9184423pubmed:articleTitleA reference material for harmonisation of D-dimer assays. Fibrinogen Subcommittee of the Scientific and Standardization Committee of the International Society of Thrombosis and Haemostasis.lld:pubmed
pubmed-article:9184423pubmed:affiliationGaubius Laboratory, Leiden, The Netherlands.lld:pubmed
pubmed-article:9184423pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:9184423pubmed:publicationTypeGuidelinelld:pubmed
pubmed-article:9184423pubmed:publicationTypeComparative Studylld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:9184423lld:pubmed