Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
5
|
pubmed:dateCreated |
1997-8-18
|
pubmed:abstractText |
The term "D-dimer assay" suggests, that these assays report the concentrations of the end-stage degradation product of crosslinked fibrin. This hardly occurs in patients. Degradation products of cross-linked fibrin rather occur with a wide range of molecular weights, and comprise various numbers of the D-dimer motif. Moreover, the numerical values obtained with different "D-dimer" assays vary widely. The variations are probably due to differences in reactivity of the various monoclonal antibodies used with the various D-dimer containing degradation products as they occur in patients; and to the various calibrators with a value assigned by the manufacturers. For the reasons indicated above a calibrator in the strict sense (e.g., pure D-dimer) is not feasible. This study shows that: it appears feasible to generate a conversion factor for each of the "D-dimer" assays studied, which will make the widely varying results obtained with these kits comparable; that the conversion factors can be based on a pool of real patient samples; and that the conversion factors are pool-independent. The next and final step in this study is to prepare and make available an international reference material for use by manufacturers and others facing a comparison problem. This is being carried out, in collaboration with the NIBSC (Dr. P. Gaffney), and the material is expected to be available in early 1997.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
May
|
pubmed:issn |
0340-6245
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
77
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
1031-3
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading |
pubmed-meshheading:9184423-Antifibrinolytic Agents,
pubmed-meshheading:9184423-Female,
pubmed-meshheading:9184423-Fibrin Fibrinogen Degradation Products,
pubmed-meshheading:9184423-Humans,
pubmed-meshheading:9184423-Immunoenzyme Techniques,
pubmed-meshheading:9184423-Laboratories,
pubmed-meshheading:9184423-Male,
pubmed-meshheading:9184423-Netherlands,
pubmed-meshheading:9184423-Reference Standards,
pubmed-meshheading:9184423-Regression Analysis
|
pubmed:year |
1997
|
pubmed:articleTitle |
A reference material for harmonisation of D-dimer assays. Fibrinogen Subcommittee of the Scientific and Standardization Committee of the International Society of Thrombosis and Haemostasis.
|
pubmed:affiliation |
Gaubius Laboratory, Leiden, The Netherlands.
|
pubmed:publicationType |
Journal Article,
Guideline,
Comparative Study
|