pubmed:abstractText
Intraoperative autotransfusion (MAT), preoperative autologous blood donation, and preoperative normovolaemic haemodilution are three different methods to avoid homologous blood transfusion during surgical procedures. The controversial use of MAT via cell saver in tumour surgery as well as contamination of the operative field with urine illustrate the particular difficulties of autologous blood transfusion in connection with radical prostatectomy. We investigated changes in the osmotic resistance of the retransfused red blood cells (RBC), bacterial contamination, changes in coagulation parameters, and the presence of tumour cells.
pubmed:language
ger
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:month
Feb
pubmed:issn
0003-2417
pubmed:author
pubmed:issnType
Print
pubmed:volume
46
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
101-7
pubmed:dateRevised
2006-11-15
pubmed:meshHeading
pubmed:year
1997
pubmed:articleTitle
[Advantages and limitations of intraoperative mechanical autotransfusion in al prostatectomies].
pubmed:affiliation
Klinik für Anästhesiologie der Universität Erlangen-Nürnberg.
pubmed:publicationType