Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
2
|
pubmed:dateCreated |
1997-2-26
|
pubmed:abstractText |
We noticed that some patients with arteriovenous (AV) fistula on chronic hemodialysis experience pain in the limb with the fistula a short time after being connected to the dialysis machine. We postulated that the pain is caused by relative ischemia and therefore performed this study to determine whether oxygen saturation (SaO2) of the extremities with AV fistula decreases during hemodialysis. Seventy-two patients with a side-to-side primary AV fistula were evaluated by pulse oxymetry. SaO2 was measured before hemodialysis and 20 minutes after initiation of dialysis. The contralateral arm served as a control. In 48 patients, SaO2 difference between the arms of each patient before hemodialysis was less than 4%. SaO2 values of this group of patients did not change significantly 20 minutes after initiation of dialysis. In 24 patients, SaO2 differences between the hands of each patient before hemodialysis were 4% or more. In this group of patients, SaO2 values of the hands with the AV fistula decreased significantly 20 minutes after hemodialysis from a mean of 90.85 +/- 2.84% to 81.60 +/- 3.94 (P < 0.001). SaO2 remained unchanged in the contralateral arm. Nine patients in this group complained of pain and change in sensation in the arm with the fistula during hemodialysis. One patient complained of severe pain in the arm with the fistula before hemodialysis, and SaO2 was unmeasurable. We conclude that, in some patients, SaO2 of the arm with the AV fistula decreases only during hemodialysis. This phenomenon may be symptomatic. A predialysis SaO2 difference of 4% or more between the arms predicts decreased SaO2 of the arm with the AV fistula during hemodialysis.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Feb
|
pubmed:issn |
0272-6386
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
29
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
230-2
|
pubmed:dateRevised |
2004-11-17
|
pubmed:meshHeading |
pubmed-meshheading:9016894-Arm,
pubmed-meshheading:9016894-Arteriovenous Shunt, Surgical,
pubmed-meshheading:9016894-Humans,
pubmed-meshheading:9016894-Ischemia,
pubmed-meshheading:9016894-Oximetry,
pubmed-meshheading:9016894-Oxygen,
pubmed-meshheading:9016894-Pain,
pubmed-meshheading:9016894-Prospective Studies,
pubmed-meshheading:9016894-Renal Dialysis
|
pubmed:year |
1997
|
pubmed:articleTitle |
Pulse oxymetry evaluation of oxygen saturation in the upper extremity with an arteriovenous fistula before and during hemodialysis.
|
pubmed:affiliation |
Department of Surgery B, Sackler Faculty of Medicine, Tel Aviv University, Israel.
|
pubmed:publicationType |
Journal Article
|